What would be the proper choice between shell and frame for modelling 1.2m x 0.6m vertical element?
In a building I am studying expansion joints. All columns are 600mm dia circular. Except some vertical elements 1200x600mm.
1) The question is what system for seismic behaviour you would...
Do you guyz think that this stiff plate (lets say 10mm) is adequate to provide resistance to lateral torsional buckling of flanges? This is the part of a long truss.
Please guide me about calculating the rotational stiffness factor for soil. How we calculate this and what are the values used for this factor normally?
I need to design a boundary wall 4m high for a blast loading which is 2m away from the wall. Please mention some reference to calculate the load and in your opinion how much will be the pressure on the boundary wall in this situation?
I want to confirm if there is any difference between designing a composite steel beam with concrete slab
and the other option is:
instead of concrete slab what if I have only concrete beam.
I want them to behave as composite beam...so are the design steps and concepts same as in case of...
What is the best procedure to apply wind loads on 20m high minaret with plan dimensions of 3mx3m? According to ASCE there is a method for "Chimneys, Tanks, Rooftop, Equipment, & Similar Structures"..resulting in concentrated wind force
I shall use this method or the regular method where we...
Hi guyz!
How would you design a concrete inclined wall? in ETABS we cannot assign piers to inclined walls..So the other way i think is to use moment contours...but how to design by moment contours?
A wall has 2 out of plane bending moments, 2 out of plane shear components, 1 in plane shear and...
Is there any NOTIONAL LOAD provision in ACI code as it is present in BS code.
The concept is to apply some %age of gravity load as horizontal load to the building and check its stability but I am not sure if this clause is present in ACI/UBC/ASCE/IBC?
1) How to calculate encased steel column modulus of elasticity?
2) How to model this in ETABS and what modifiers to be applied to check axia shortening of this section?
3) What is the limit for gravity only sway of the building? H/1000?
"Hello,
We want to model a very complex 3d structure. Its having variable heights of floors. So we cannot intersect our building with etabs story lines. Additionaly, the model will be imported from 3d CAD in one go. So we have decided to define a single story height of lets say 20m in ETABS and...