we have two restriction orifices in our sea water return line. We would like to open these orifices partially whenever choked with sea shells and plastic material. Can somebody help me in this. Can I convert the existing multi hole RO into Slide gate valve with multi hole orifice...something...
In one of our unit, we kept two restriction orifices in sea water return line (72") to create back pressure for adequate sea water distribution to other units. Now the problem is these orifices are choking with plastic material, which was lined inside a cement lined carbon steel piping. What I...
In one of our unit, we have cement lined carbon steel piping for sea water (72" line and 15000 m³/h). Return line is having two multi hole orifices, which are getting choked with cement material. In 2006, we have provided one more plastic lining to protect the cement lines. But this time...
In Our site there are total seven plants and Sea water is supplied to some of the plants. The first plant near to the sea water supply having issues in return line. Because of high pressure drop available, we have inserted a multi hole orifice in the return line (72"). Then we found flashing of...
In Ethylene Glycol unit, recently we have decided to route the vaccum condensate of PGU Refining column two stage ejector system to an existing vessel, which is having a spare nozzle at the bottom of the vessel. The vaccum required in the column is 49 mmHg. The vertical distance between...
We are thinkng of transfering isopentane from iso container to an internal floating roof storage tank, and to store it. In Middle East, as you know the ambient temperatures are very high, and the isopentane boiling point is 27.8°C, we are thinking of providing chiller and maintain the tank...
In one of our unit, the existing barometric leg from a two stage ejector-condenser system is routed to OWS. Because of some TOC(Total Organic Comp)at utilities issue, proposed to divert the stream to other existing vessel. We have the problem of space constraint. The proposed vessel is far away...
I would request somebody to help me in understanding the concept of using static pressure in Fans and blowers performance curves. Normally for centrifugal pumps there will be a characteristic curve of differential head vs Flow. Why we use statis pressure rather than the total pressure for...
We are going to install a filter in tailgas compressor suction line of (18"). I would like to go with out any requirement of PSV. As it is a gas filled line, there is no possibility of pool fire scenario. If i keep open the both inlet and outlet valves in "Car Seal Open" position, I can omit the...
Hi,