Per AISC Design guide, multiple rectangular opening spacing (clear spacing) must be greater than or equal to the height of the opening. Then in addition to that, clear spacing in composite beams must be greater than 2 x beam depth. This seems excessive for a 24" or 30" beam with multiple small...
Can anyone suggest guide/code reference for flange plated beam splice that affects beam stiffness/deflection? I have a 90 ft roof purlin span with a midspan beam splice (at request of fabricator). Beam design was governed by deflection.
We are currently evaluating two software programs for P-T slab structure design: ADAPT Builder and RAM Concept (we already have the rest of the RAM structural suite). Does anyone have any comments//concerns/suggestions between these two software programs?
Why is there not a widespread product for a vertical slide clip to attach wood balloon framed walls to floors? This connection is very common in the metal stud industry.
I have an existing two way concrete flat slab built in 1950s. Owner wants to bring the structure to current code for new occupancy. Stress levels work for flexure (shear is a different story), however the bottom rebar splice requirements have changed. I understand the column strip bottom steel...
Designing a building addition in New York State. The addition will be structurally separate. The existing 2 story building does not have any obvious lateral resistance shown in existing drawings. Only thought is the exterior masonry walls help provide lateral resistance. How do I approximate a...
Hello all,
I am tasked with structural design of a conventional steel framed operating floor of a paper machine building. The roof and crane above will be a pre-engineered building. I am unsure on floor loading since I have reviewed similar projects with varying loads of 400 - 600 psf (with...
I have a split slab parking deck project in northern climate. It is a steel framed floor with a reinforced concrete slab. A waterproof membrane was adhered to the slab then protected by a protection board and a 3" concrete surface topping. The topping has caulked saw cut joints at 7' on center...
We have a 100 year old concrete building with steel brackets bolted to concrete columns (it appears threaded rods were cast into the columns). These brackets once held up a crane rail. We would like to use these brackets for another application however there is no information on the crane or...