  1. james64

    Transformer enclosure type for lift station

    Hello, I am working on a small lift station(pumping storm) that requires a 75 kVA transformer. "Is a Transformer enclosure with a Type 2 driphood enclosure sufficient or should it be a NEMA 4 enclosure?"
  2. james64

    VFD blow up

    Hi all, I am experiencing a problem with a VFD that seems to be getting damaged when the motor starts. The overcurrent protection of the VFD is set to around 70A, while the motor has a full load current of approximately 80A, 600V, 3-phase at FLA. I am wondering whether the issue may be caused...
  3. james64

    How to size isolation transformer to reduce fault current ?

    Hi all, I am experiencing an issue with a low-fault current panel X that is connected to an upstream feeder breaker with a capacity of 600V/400A. The client wishes to increase the fault current in the current panel X, but replacing the panel is a challenging task. To resolve the issue, we have...
  4. james64

    How many additional load available for existing transformer ?

    We have a unit new 75kVA dry transformer on site now. I would like to know how many of the existing transformers can handle more load in the future. After checking the existing demand load, around 50kVA was used up to date. The name plates say that low-temperature rise of 80 C and the insulation...
  5. james64

    MLO(Main Lug Only) vs MCB(Main Circuit Breaker)

    Hello, I am working on the panel schedule, and I noticed that some panel has MLO, and some panel has MCB. I believe that the omission of a main breaker in many of these cases is due to cost and perhaps in some cases available panel real estate. Is there any rule for MLO or MCB? I am not...
  6. james64

    Grounding System Design Software

    Hi all, Currently, I am designing the grounding system and I am exploring software options that can simulate a grounding plate instead of mesh grounding. I am aware that ETAP has a grounding design function, but I am not sure if it can support grounding plate design. Can you recommend any...
  7. james64

    GFI receptacle installation

    Hi all, I have a renovation related GFI installation. i need to replace normal receptacle with GFI receptacle. Does GFI receptacle has to have GFI breaker at the same time? Thank in advance !!
  8. james64

    What are the steps to follow when sizing a main circuit breaker?

    Hi all, I have a switchboard with 347/600V c/w 600A which has panel A with demand load 100A , panel B with demand load 200A, panel C with demand load 200A, panel D with demand load 200A. I am sure if 600A is right main breaker size or not. Can you please advise how to size main breaker of...
  9. james64

    MCA & COOLING LOAD

    Hello, I am evaluating the power consumption at steady load of a RTU(roof top unit) which operate at 600V an MCA of 8.2A. So that would come out kw = 600 x 8.2 x 1.73 = 7.1 kw. But cooling power input (w/o blower)load says only 2.51kW as per name plate, which load should I consider for load...
  10. james64

    Elevator electrical name plate

    Hello all, I am currently designing an elevator and machine room for subway. Electrical specification say as below MAXIMUM ALLOWABLE VOLTAGE VARIATION IS +/- 10% KONE CALC THE FOLLOWING FOR THIS ELEVATOR DUTY NAME PLATE AMPS : 15 Max ACCEL AMPS : 26 PROTECTION DEVICE REQUIRED PRIOR TO...
  11. james64

    Infra Red heater starter

    Hello, All I am working IR(infra Red)heater installation with heater starter on site. Electrical drawing provide one circuit for two IR heater with starter. It seems that starter was composed of timer, thermostat controller, contact relay and others. As each IR starter require own starter...
  12. james64

    What kind of fault current calculation is required during ground grid design

    Hi all, i'm working on the preliminary design for a subway ground grid. I got informed the soil resistivity from the site and it is 300 ohm-m. so I started playing with the number using IEEE 80-2000. So my concern is , what kind of simulation is required for sizing grid grounding. For...
  13. james64

    LOADBANK PHASE 3PH 3W or 3PH 4W

    Hello, I am working on an SPECIFICATION low voltage 100kW loadbank. Regarding rating, what specification is correct? For example, 3ph 3w or 3ph 4w.
  14. james64

    Multi- Functional Relay data entry issue using ETAP

    Hi all, When I put the data in the multi function relay from the library ETAP, it was not stored. Even enabled was checked, in other word, check this box to enable the parameters for selected supplied model number. Have any ETAP users encountered this problem, and how is it resolved ?
  15. james64

    CDEGS error

    Hi everyone, I am learning CDEGS recently, I found out "there are defects in the grounding grid during simulation, Use the diagnostic tool for more information. Does any body experience this problem? Thank in advance!!
  16. james64

    Touch voltage calculation

    Hello my friends, I am struggling to calculate touch, step and GPR according to IEEE std 80, 2000. soil resistance: 2500 OHM*M fault current : 10kA current division factor : 20% Can I calculate standard and calculation values above without using software ? The result is quite strange to me...