  1. bdfig

    Bus 1sec fault rating vs IEC 60909-0

    Hi, I have a bus which has a 25kA/1sec fault rating. Is this normally compared to IEC 60909-0 sub-transient, transient or steady state fault level? Any help is appreciated.
  2. bdfig

    IEEE 1584 Equation 4 Units

    Hi, in IEEE 1584 equation (4) (page 11) it states "En is the incident energy (J/cm^2) normalised..." Then in equation (6) E = 4.184*Cf*En(t/0.2)(610^x/D^x) E is the incident energy (J/cm^2) and in section E.3.1 Equation (E.1) E= Cf*En*(t/0.2)(610^x/D^x) in cal/cm^2 Is En from equation (4) in...
  3. bdfig

    IEC 60909 Transformer Impedance Correction Factor

    Hi, I was wondering what reason is behind IEC 60909's transformer impedance correction factor. Is this replace transformer impedance tolerance, or should they both be applied?
  4. bdfig

    Instantaneous Override Current (ABB Tmax)

    Hi, does anyone know what the instantaneous override current of an ABB Tmax T4S circuit breaker with PR222 trip unit is? I cannot seem to find an ABB document which has this.
  5. bdfig

    Circuit Breaker Uninterrupted Setting

    Hi all, I am currently using ABB circuit breakers, which has an uninterruptible current rating equal to their frame size. However the long time pickup of their associated trip devices has a tolerance of 1.05 to 1.20. Does the continuous current rating of the CB preclude me from using the...
  6. bdfig

    ETAP LV Circuit Breaker Opening Times

    Hi all, In ETAP I have added LV circuit breaker opening times in the "Min. Delay" field under the Ratings Tab. However the opening times do not appear in the sequence of events or arc flash study results, and the arc flash fault clearing times appear to just use the trip device TCC time at the...
  7. bdfig

    ETAP Cable Zero Sequence Impedance for L-G faults

    When attempting to validate IEC 60909 L-G fault calculations from ETAP, I find that the fault levels are higher than I calculated. It appears that ETAP is doing Sqrt(3) c U / |2*Z1 + Z0|, with Z0 taken directly from the R0 and X0 in the cable library entry, rather than using Z0 = Z0 phase...