Hi all,
I am currently working on a Thermosolar Plant where a molten salts are the fluid to be heated in order to obtain steam afterwards. This molten salt line goes up through a tower of 250 m, and as the salts solidify at high temperatures, to avoid damage on the flanges face it was decided...
ASME B31.3 claims that no Charpy Test is required for A106 Gr. B if the design temperature is equal or above -29ºC, and I have doubts if this can also apply to ASME B31.8, since it does not specify.
For your information these pipes shall be used for compression gas station in Mexico (design...
Dear all,
Its not very long ago that I am into valve engineering and I am finding problems to understand some matters of fire test in valves. How can it be that we are asking for an API 609 soft seated valve that acomplish requirements of API 607, as far as I know PTFE should not be used with...
Dear all,
One of my vendors is offering welded in seats for valves that required threaded rings. As per my specs. this deviation is acceptable, but I am wondering what is the procedure to weld an overlay of 316 on a A216 WCB body valve.... does anyone know?