  1. yazguli

    pipe coating

    Hi everybody! Would you please help me to understand the terms in the attached image? Thank you a lot.
  2. yazguli

    effectiveness of a "penetrating fin"

    Hi If you make a cut on the inner pipe of a double pipe heat exchanger or make a hole on it and attach a rectangular or a pin shaped fin on (in) it,(and of course, weld it) so that it is extended from inside of the pipe to it's outside,how would the fin effectiveness be changed? I wonder if in...
  3. yazguli

    thread403-400808 Hi A garbage chu

    thread403-400808 Hi A garbage chute duct is simultaneously subject to positive and negative pressure at sections downstream and upstream of the garbage when it is falling down. So I think it is not a good idea to install the exhaust fan on the upper end of it. Generally speaking, a separate duct...
  4. yazguli

    cooling tower question

    Hi everybody In rating a cooling tower, dry bulb temperature of air is not considered. On the other hand the ratio of latent to sensible heat transfer is dependent on it. If the thermal performance of a cooling tower is considered as the sum of its ability to sensible heat transfer and latent...
  5. yazguli

    single coil

    Hi every body If there is no need to have cooling and heating simultaneously and if there are control valves on air handling units ,is it enough to have just a single coil for both heating and cooling?
  6. yazguli

    reverse return question

    Hi In a reverse return heating system does it matter if the pump is installed on return or supply line just because it is a reverse return system?
  7. yazguli

    NPSH question

    Hi everybody This thread is interesting for me very much. Unfortunately I can't get Biginch's diagram.Any help please? thread407-199822
  8. yazguli

    thermosiphon question

    1 -Is there something like "pressure gradient" or "driving force gradient" in a thermosiphon system?If so,how is it drawn? 2 - Suppose a simple thermosiphon system of a heat source at bottom ,a sink at top and two risers.If there is another sink in the middle of source and sink how the system...
  9. yazguli

    density and mass percentage

    1- Is it possible to calculate the density of a solution (for example Li Br solution) from solvent's mass percentage? 2 - Where can I find a table or a chart for Li Br - water solution density?
  10. yazguli

    blind caps vs blind caps

    Is there any rule for when to use blind flanges and when to use blind caps for headers (say parallel pumps headers)?
  11. yazguli

    gravity flow as pumping

    If we suppose the flow at the outlet of a water tank to be the discharge of a pump,and if we connect a pump to this outlet it is as if we have two pumps in series.In such arrangement we don't expect the flow rate to be increased specially if the system curve is near to flat.But in practice the...
  12. yazguli

    riser sizing

    Sorry for asking such a basic question! In a 6 floor car parking the design area consists of 12 sprinklers in 6th floor.Suppose the flow rate to be 240 g.p.m and the feed main pipe size to be 3".What will the flow rate for which the riser size will be calculated at lower floors?The same 240...