  1. AskOR

    Knock out pots as "Piping Components"

    If a knock out pot is constructed simply out of 18 inch pipe and fittings, can it be considered a "piping component" under API to avoid relief calculations? Probably the only credible scenario would be fire (that is, if its not considered a piping component). The equipment is not otherwise...
  2. AskOR

    ASME Section 1 historical relief requirement

    Hello- I am sizing relief devices for a client who has an ASME Section 1 boiler. Per the current code, if I set the valve at the MAWP, then my overpressure is limited to 6%. My client wants to invoke relief requirements for equipment at the time of installation (not necessarily current...
  3. AskOR

    ASME Section 1 relief valve on non-steam side

    Hello all- I'm sizing a pressure relief valve on the non-steam producing side of my ASME Section 1 boiler. My entire boiler (shell and tube) are rated as ASME Section 1 per the U-1 form. However, does the non-steam side relief valve have to comply with Section 1 (106% accumulation, etc)? Thanks-
  4. AskOR

    Distillation Curve Methods

    I have a process stream that has been characterized by Distillation Method UOP76, "High Vacuum Distillation of High Boiling Range Petroleum Products". I need to enter this into my simulation model, but only have options for ASTM or TBP methods. Does anyone know if there is a way to convert...
  5. AskOR

    API 12F Inbreathing requirement

    Does anyone know if the 12th edition of API 12F changed the thermal inbreathing requirement to be consistent with the 6th edition API 2000 calculation which is much more conservative than the previous method based on tank capacity?
  6. AskOR

    "Atmospheric" MAWP for a API 650 Tank

    Hi- I'm sizing conservation vents and emergency vents for several older API 650 tanks and need some advice. The mechanical drawings for the tanks say the MAWP is "atmospheric", but there is a noted test pressure of 2-3 psig. These tanks are NOT API 650 appendix F tanks, so the MAWP is...