Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. irishengdave

    Construction joints

    I practiced in the british isles for 10 years and in vertical walls, we always just scabbled (exposed the aggregates) at the joint carried the rebar through and assumed it has the same shear capacity as a monolithic joint. I practice in N America (Canada) now and they always cast a shear key in...
  2. irishengdave

    Bond capacity of spiral duct in precast concrete connection deatail

    I'm designing a connection in Precast concrete. Does anyone have any published values of bond capacity for steel spiral ducts cast into concrete?
  3. irishengdave

    QUICK ESTIMATE FOR SWAY DEFLECTION IN A MULTISTOREY STEEL MOMENT FRAME

    I'm preparing for the IStructE Chartered member examination in January. I'm looking for a very "quick and dirty" way of estimating the sway deflection under wind load in a steel building moment frame. Typical building bay width is 6 to 8 m and storey height 3 to 4 m. Could be any number of bays...
  4. irishengdave

    Pipe Pile Plugged and Cored Conditions questions

    Hi There, I am researching how to determine the axial capacity of open ended tubular piles in primarily cohesive material. The methods I have read about say you should check the plugged and unplugged conditions. 1. The plugged capacity = Outer skin resistance + Base resistance of a closed...
  5. irishengdave

    Grout Problem

    Attached is a picture of a grouted baseplate. Our site rep is telling me the edges of the grout (microsil) are crumbling and have a honeycombed appearance. It can be broken up in your hand quite easily. Any ideas about what happened? I don't know if the strength has been compromised or...
  6. irishengdave

    Overturning of footing with uplift

    Hi -- I'm looking at a footing and checking overturning. Criteria as follows:- 1) Uplift = 200 kN 2) Shear = 100 kN 3) Weight Soil Backfill = 200 kN 4) Depth = 2 m 5) Width = 2m Refer to sketch attached. Question: Is the footing stable in overturning or not? Assume that loads are un factored...
  7. irishengdave

    ASCE building or non building similar to a building

    We are designing a 9 storey steel industrial building supporting mechanical equipment. There is a designated area where 5/6 people work 5 days over 40 hrs per week. The building is cladded. What category does it fit into, building or non building similar to a building? Problem is, if we design...

Part and Inventory Search