Hi,
I have a client requiring a small unit (consists of lab size exchangers and membrane modules) to meet DIN standards. The system design pressure is 50 psig and max temperature 100ºC. As in North America we deal with ASME only, what is required to meet the DIN standards? Any help or...
Hi,
I have a small lab unit that consists of a small vessel (ASME UM stamped), tubing and some other fittings. The total volume of the unit is less than 1.5 cu ft, and none of the components have diameter larger than 6". The unit could operate upto 50 PSIG. Does this need to be a registered...
Hi,
Can a shell and tube heat exchanger below duty of 200,000 BTU/hr used to heat water to 75ºC with high temperature steam be exempted from ASME code requirements?
Thanks,
Mehak
Hi,
I am working on a low pressure sugar solution system. A shell&tube exchanger is used to maintain temperature in the system. The sugar solution flows through the tube side (process side, 25psi and 80ºC max)and superheated steam under vacuum is used on the shell side (100 torr and 176ºC...