Hi,
I'm a medical imaging engineer well outside my comfort zone - I hope you can give some insight on a flow experiment I'm designing.
We're trying to generate a controlled pulsatile flow in a 1" pipe. The peak flow is around 0.6 m/s (2 ft/s), and the pulse should go from zero to peak to zero...
Hi fellow engineers,
I'm a medical imaging engineer way outside my comfort zone, and I hope you can give some insight.
We're trying to generate fast, accurate pulses of water in a 1" pipe. We want a peak velocity of 0.6 m/s and a pulse lenght of 300 ms. Our current idea is to take a 1"...
Hi,
We're designing a flow experiment where we need to produce a controlled pulse of water in a pipe. Our current design idea is based on a constant head tank, a flow meter, a proportional valve and a control system as follows:
Image from Gharib et al. J Fluid Mech 1998.