Hi
I have a question with "sifs".
For example, when I recalculate SIFs (Nozzle with reinforced pad with FE SIF). I enter the values on the 3 branches but should i also indicate the type of the branch?
I get different results if i indicate or not "reinforced" in the box "type".
In my opinion...
Hi everyone,
I'm facing to a problem when i calculate hs/R (0.25). It comes out of the table 9.3.4.2, how do you proceede when you get this?
ncyl =3
In this case, hs/R =0.25 and ncyl =3 should i check paragraph 9.3.4.b?
Thanks for your help
Hi everyone,
I have to calculate flow rates from emergency venting for tank wich looks like to a pressure vessel. The tank is supported by legs. The bottom is an ellipsoidal head and the top is a flat head.
Pmax :100mbar
Vaccum : 30 mbar
Temperature : 135 °C
Which code do i use to get it. I...