  1. doingwhat

    13D/13R closet door

    Hi all, Do we need to install a fire sprinkler head in a closet that is less than 24 square feet but without a closet door ? Does the closet (without s door) need to have a minimum lintel depth of 8 inches? Ray
  2. doingwhat

    Max Head Coverage in attic / concealed space

    a 1 story building with a 2x10 wood trusses and the roof pitch is less than 4:12 Is the space between the wood trusses and the suspended ceiling an attic or concealed space? What is the difference between attic and concealed space? So in this case, what is the maximum coverage per head in this...
  3. doingwhat

    Definition of Branchline vs Cross mains

    Our concern is the that every time we branch off from a primary branchline to pick two or three heads in small rooms the preceding branchline will be viewed as a cross main and then would have to be seismically braced regardless of size. If I only use all 1" to 1-1/2" CPVC for a small 13R...
  4. doingwhat

    How do i select the size of the air compressor for a dry pipe system?

    System demand for the dry pipe is 160.6 gpm length of dry pipe 4" main is about 121 ft length of the 2-1/2" branch line is about 106 ft So how do i select the size of the air compressor?
  5. doingwhat

    Elevation Gain formula

    Provide a calculation showing that the 5’-4” long branch line and drop, including the elevation gain from the cooler ceiling to the existing branch line at .445 X 100 = 45.5gpm, is less than the staring pressure for the roof level sprinklers at .5 X 11’-6” X 8’ = 46gpm. If the friction loss...
  6. doingwhat

    pressure loss for the hose valve

    How do I account the pressure loss for the hose valve? From table 8.3.1.3 NFPA 14 I figure the equivalent length should be 31+12=43 ft (hose+tee) So where do i add this length in the hass program ?
  7. doingwhat

    Water allowance for private hydrant

    I have a question regarding water allowance for private hydrant. According to NFPA 13, 11.1.6.2 Water allowance for outside hose shall be added to the sprinkler requirement at the city main or a private hydrant, whichever is closer to the system riser. Project info. 5 stories office building...
  8. doingwhat

    In Rack Sprinkler

    I have a project that we have to install the in-rack sprinkler for plastic group A. The existing density for the ceiling sprinkler is 0.45 GPM/sq ft. / 3,000s.f. Storage height is 25ft and Ceiling height is 25'-10", Non-excapsulated, single row rack, My question is do I need a separate control...
  9. doingwhat

    Why tyco sprinkler head is much more expensive than globe sprinkler?

    Anyone use globe sprinkler before?
  10. doingwhat

    what is the minuminm density requirement for an existing warehouse (retail packaging)

    - building height is about 17 ft - storage height is less than 12 ft The warehouse will be used to store/retail packaging for sunglasses. Is this belong to ordinary hazard group 2 (Mercantile? )