Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SDETERS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Okiryu
  • Content: Threads
  • Order by date
  1. Okiryu

    @ BigH - Asphalt book

    Hi BigH, thanks for your response to my question about the asphalt book. Sorry, I lost all my emails from the account that I used to communicate with you the last time... could you please send me your email address please?
  2. Okiryu

    Asphalt material book

    Hi ! Can anyone recommend me a good reference book for asphalt materials (design and construction)? I need to do some literature research to answer some questions for an AC pavement that has some surface defects. Thank you !
  3. Okiryu

    Asphalt testing

    Hi, what could be the best tests to verify the quality of the asphalt? New asphalt was placed 5 months ago but not open to real traffic yet. Client is concerned about tire marks are left on the asphalt. These marks are from steering the wheels without movement. Asphalt is PG 60/80 with...
  4. Okiryu

    Boring Log Software

    Hi, can anyone recommend a good software for preparing boring logs? We have been using AutoCad but some people are not familiar with it so trying to find a software... Thanks!
  5. Okiryu

    Soil Friction resistance against uplift

    We are designing a foundation for a water tank. The foundation is a circular continuous shallow foundation on weathered limestone rock. Soils are very competent. The foundation shape is like a rectangular pedestal (it is NOT the typical inverted T-shape shallow foundation shape). We are...
  6. Okiryu

    Constructing adjacent to an existing CMU Wall

    Hi all, our client wants to build a small house adjacent to an existing CMU wall which is old and showing some cracking. However, excessive deflection or settlement was not observed. See attached photos so you have an idea of the wall/site conditions. I expect that this wall is retaining clayey...
  7. Okiryu

    Concrete Pavement Dowels

    I am involved in the construction of a new concrete hardstand (200 mm thick [8"]). The dowels are 20 mm diameter x 400 mm long, spaced @ 300 mm on center. The center of the dowel is at 110 mm below the surface of the concrete surface. Project requirements indicate that the dowels shall be...
  8. Okiryu

    Lightweight polystyrene fill for flexible pavement subgrade

    Have you ever used lightweight EPS fill as flexible/rigid pavement subgrade? If yes, what CBR/k can be used? Perhaps, the EPS compressive strength can be correlated with CBR/k? Traffic is composed of medium size forklifts (10-15 kip axle forklift, max 50 operations/day in 25 yrs design life)...
  9. Okiryu

    Thickness of the subgrade

    Hi ! In the US, what is the thickness of the subgrade? Here in Japan, we consider subgrade soils to extent 1 meter below the subbase course... just curious about what are the considerations for subgrade thickness in the US... For example, if design guidelines indicate that the subgrade should...
  10. Okiryu

    Solar reflective coating in flexible AC pavements

    We are experiencing some failures in our pavements that were coated with solar reflective coatings (Street Bond) (https://squareonepaving.com/products/street-bond-150-coating/overview/). See also attached photo. Basically, when we turn the wheels on the spot, the coating is peeling off. This...
  11. Okiryu

    Removal of expansive soils under pavements

    I have a new project which I have to deal with expansive soils... do you know any design approaches for pavement design in subgrades with expansive clays? I am looking for methods to determine the thickness of expansive clays to be removed in order to provide adequate support for this new...
  12. Okiryu

    "RX" in soil borings logs

    Hi, I had a boring log which shows "RX" in the USCS column. Obviously RX is not an ID for soil classification so I assume that it indicates "Bedrock". Is this assumption correct? Thanks !
  13. Okiryu

    Relative Density

    Quick question: in the US, what is the typical procedure to obtain the relative density? Are any limitations for the fine contents for the sand samples?
  14. Okiryu

    Foundations for shear walls

    Just looking for input from the SEs here: if I have a building which the structural system is composed of exterior shear walls with columns and interior columns, do the exterior shear walls require their own foundations (i.e wall footings) or can they be supported on grade beams which will...
  15. Okiryu

    Congrats PEInc !!

    I just looked at the Geostrata magazine from the GeoInstitute of ASCE and found this article... When I contacted John some time ago to get his input for an underpinning project, he was very helpful and responsive. I know he is a busy guy but, he took the time to look at the problem and provided...
  16. Okiryu

    DCP vs. Compaction degree and qu vs. E correlations

    Does anyone know references for DCP vs. Compaction degree correlations? Also, I am looking for unconfined compression strengths from pocket penetrometer readings vs. elastic modulus correlations. Any reference will be greatly appreciated !
  17. Okiryu

    New opening in exiting wall

    Hi, I move this thread to the structural forum (it was in the demolition forum) since I think that people looks more at this forum.... We are doing a preliminary study for addition an opening in a wall for an existing tank. The existing wall is very thick (2 m thick) concrete wall. The tank is...
  18. Okiryu

    Concrete on top of a liner in sloped area

    We are designing a project where the concept design shows a concrete slab on top of a liner. This is for a secondary containment for an above-ground fuel tank. However, there is a slope (between 3:1 and 2:1) in one of the sides of the containment where concrete on top of the liner is also...
  19. Okiryu

    Impact of Seismic Site Classification

    Hi !... I do geotech so, sorry if this is a dumb question: what are the implications in the structural design if we change the class from D to E or F? Say, we have a mid size building (5 story) so the period may be about 0.5 seconds. My understanding is that for LOW periods, there is a trend...
  20. Okiryu

    Wire mesh under saw cut joint

    I have a slab on grade, 6 and 8 inches thick. No vehicle loading, just well distributed load (liquid). Saw cut is 40 mm depth and wire mesh is 50 mm below the surface of the slab. Do I needs to cut the wire mesh under the saw cut joints or can the wire mesh be continuous thru the slab...

Part and Inventory Search