Hello,
I'm troubleshooting a pump system and am hoping the community here can provide some insight into what kind of issue I might be dealing with.
First some background:
System consists of two parallel centrifugal pumps feeding two parallel recip pumps
Centrifugal pumps are on VFDs but have...
Hello,
I have been asked to look into whether or not it is possible to redesign/re-certify existing storage tanks that were designed and constructed to API 12F to be compliant with API 650.
My initial feeling is that this will not be possible due to the more stringent examination requirements...
Hello,
I am trying to determine the bolt loading requirements for the channel head to vessel shell connection on one of our heat exchangers. There is a fixed tubesheet between the two flanges.
Searching for an approach to calculate the bolt loading requirements for this type or arrangement...