  1. releky

    Rusts in bars inside beams

    If there are rusts inside bars inside beams.. how do you remove the rusts when concrete enclosed it. And If you inject epoxy into any hairline opening and the rust is isolated, would the rust further corrode the remaining bar inside the beam? How is this thing usually handled? This is similar...
  2. releky

    Beam Span length

    When one say beam span, is it the clear span of the beam or the span from center of one column to another? Does it vary with different codes? For example. My beam has length of 5.2 meters clear span but 5.65 meters center to center of the supporting columns. So is my beam length 5.2 or 5.65...
  3. releky

    Seismic Plastic Hinge Moment Strength Upgrade

    Hi, to those who have discussed with me before about missing seismic shear strength in the building I'm managing as engineer.. I'll update you with the situation concerning attempt for shear upgrade. Based on the designer calculations which I have seen and discussed with them. Shear from...
  4. releky

    Probable Shear in Etabs

    The manual mentioned it can solve for probable shear Vp which is equivalent to Mpr(-)+Mpr(+)/length + (1.2DL+1.6LL/2) but even if I enable UBC 97 and chose Siesmic Zone D (Special Moment Frame), I can't find where to view Vp in Shear and Moment Diagram or elsewhere, it is not the EQ load...
  5. releky

    Repair of Plastic Hinges

    For concrete structures that form plastic hinges (in other words the flexural bars have yielded at the support), how are they commonly repaired? Just curious as a construction management engineer.
  6. releky

    Trajectories for Principal Stresses

    This is the trajectories for principal stress for uniform load http://imagizer.imageshack.us/v2/800x600q90/20/jyq8.jpg I'm looking for illustration of trajectories of principal stress for concentrated load at midspan. Has anyone encountered this?
  7. releky

    Formworks leaks

    In your practice (besides Ingenuiy), how often do you encounter formworks leak? Do you put putty all over the edge? How many contractors actually do this? Without putty covering the leak, the bottom side edge of beams can form tiny honeycomb like in the following picture...
  8. releky

    Horizontal cracks in beam below slabs

    http://img856.imageshack.us/img856/428/7cya.jpg Has anyone encountered horizontal cracks in beam right below the slabs just like in the picture above? What could have caused it?
  9. releky

    Half beam pour

    I always do beam pour all at one time or monolithic but I heard some engineers do it by stages especially those who don't use ready mix. For the case where the beam is poured one half first (left side) and then next day the other half (right side). There is a separation right in the middle...
  10. releky

    Lightweight Elevation Compound

    What plastic or synthetic elevation compound have you used or can think up to rise up the tiles from the slabs (2 to 3 inches)? Maybe hard foam? It must be so lightweight like maybe just 5kN/m^2, this is to lessen the superimposed dead load of the floor tiles.
  11. releky

    floor elevation compound

    What particular floor elevation compound do you use to make the floor or tiles higher? In my country. 100% of construction use sand mixed with cement as the filler. See the following picture: http://www.pbase.com/rele/image/153741119 The tiles and sand elevation load is this. 15 kn/cubic...
  12. releky

    Floor Tiles topping

    How many inches of topping (composing of sand, cement and adhesive mix) do you usually put in between the bare slabs and tiles ?
  13. releky

    Probable Shear Strength

    Probable Shear Strength is the equivalent of Probable Moment plastic strength in seismic design of a building. How many of you use the probable shear strength for shear in beams? This would require much more stirrups than normal. I notice many colleagues don't exactly follow it but uses codes...
  14. releky

    footings sliding on rock

    I only designed foundations for soil and never on rock (and don't intend to as there is no rock in my vicinity) but for foundations on rock... won't the foundation just slide on the rock during seismic activity since there is no friction between them?
  15. releky

    round column spiral ties

    A round column with close spiral ties can take more ultimate load because the spiral prevents the concrete from shearing outward near ultimate axial load (Pu) and has more resistance to buckling of the longitudinal ties. What would happen if the ties in a square column is made closer too than...
  16. releky

    roof cement topping on waterproof

    when you do cement topping of waterproof membrane.. is it better to use one pour for the entire 150 square meter roof or partial? the membrane topping will be 2 inches cement mixed with fine aggregates.
  17. releky

    Stiff soil or rock foundation seismic design

    What are the optimum methods to make sure the supporting foundations are able go deliver the seismic forces to very stiff soil or rock like? i usually design by usually getting the soil bearing capacity even for very stiff soil or rocklike but these are not elastic, so during seismic activities...