have 750 bbl atmospheric tank built in 1983. Shell thickness is 3/16”, roof thickness is 3/16” and bottom thickness is ¼”. How can I calculate or obtain Maximum allowable temperature on this Tank?
According API 650 maximum design temperature is 93C, but since this tank is very old and Tank name...
Hi, I have a atmospheric storage tank. I have calculated the required relieveing rates..I need to check and see if the 4" gooseneck on the roof is sufficient! How can I calculate the maximum venting through a goose neck opening?
I have a shell&tube heat exchanger with 15% of tubes plugged!! How Can enusre that exchanger is still safe to operate? is there any sort of calculation that I can perform?