Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. structure567

    Specific Requirements for Mud Mat?

    I have a question regarding the use of Mud Mat to meet the design excavation level. I am working on a deep foundation that is laying on slightly to none weathered bedrock. The excavation involved blasting which resulted in some areas that were over excavated approximately 5 feet below the...
  2. structure567

    What is the overstrength factor used on the Allowable stresses Table for aluminum beam

    I need to do some aluminum beam design and had some questions on Aluminum Design Manual(ADM) Part VI Table 2. This table shows the allowable stress but is shown as F/Ω. It does not specify what the omega value is... Does anybody what the over strength factor that is used?
  3. structure567

    Design of two steel columns with one inside another

    I am in the process of designing a steel pipe column that will require inserting a new smaller column inside of an existing column to increase the allowable strength. The smaller column will have an outside diameter 0.2" smaller than the larger column's inner diameter. If I were to treat the...
  4. structure567

    Methods to laterally brace a cantilevered steel pipe column?

    I have an 11' existing cantilevered pole that is embedded onto the ground. I would like to brace the column somehow and was wondering if there are any ways to laterally brace a pipe column at the mid height. Will it be possible to install a seismic clamp and attach a high strength rod? The pole...
  5. structure567

    Does the 0.5% minimum seismic reinforcement for deep foundation apply to solar panel pole footings?

    The solar panel is governed by wind force and I was wondering if the minimum reinforcement also apply to foundations governed by wind force. The pole footing is 5'6" deep and 30" wide. Are there any codes that specify pole footing reinforcement?
  6. structure567

    Wind load on a sloped Solar Panel?

    I am having trouble finding the right method in calculating the wind load and the net effective area on a solar panel that has a 45 degree slope. This will be attached a to a cantilever column. If I were to use ASCE 7-10, should I calculate the wind load as a solid sign or a sloped roof? Or is...
  7. structure567

    commonly used standard steel for round steel column?

    I was wondering what is the typical standard steel for hollow round column? Is it A53 or A500?
  8. structure567

    Is there a deflection limit for a sign pole?

    Trying to see if there are any specific deflection limit for a 10' cantilever steel column supporting a 6'x 6' solid sign. I am considering L/120 since this is an exterior member without any finishes. What are your thoughts? Thanks in advance.
  9. structure567

    Is the 0.6 wind load reduction(ASD) just to check deflection?

    I am designing a cantilever steel column with a solid sign and have not found an answer if I can apply the 0.6 wind load reduction for thr strength design. I know ASCE shows the ultimate wind speed and applying .6 converts it to nominal wind speed. Am I to use the .6 reduction just for...
  10. structure567

    Using ASD, is there another reason to check transient/LL deflection other than serviceability issue?

    Sorry if this is a stupid question but I was just really curious. If I were to just place a cantilever column for aesthetic purposes on the ground with only wind load being applied, is there another reason to check for deflections for the column if I used ASD load combinations?
  11. structure567

    Can you insert a smaller HSS pipe into a bigger HSS pipe to reinforce it?

    I am working on an existing cantilevered column that has an increased lateral load due to the client wanting to install a bigger sign on the existing column. We want to minimize construction so instead of replacing the existing column, I was wondering if it was possible to insert a smaller HSS...
  12. structure567

    Can you place a Hardy Frame as a cripple wall?

    Hello, I have a scenario where a client wants to have a cantilevered 2nd floor with a wide window with just barely enough room(17") for a hardy frame to resist the lateral force. Problem is that this portion of the wall needs to be supported by a steel beam underneath. I've seen details of hardy...
  13. structure567

    Two story concrete deck

    Hello, I'm trying to design a two story concrete deck. I was wondering if there is a way to model one story and obtain all the final loads and automatically apply it the lower story using SAFE.
  14. structure567

    rebars in SAFE 8 and SAFE 12

    So I'm switching over to SAFE12 and I tended to realize that the number of rebars in SAFE 8 is higher than the number of rebars in SAFE 12 when I try to design a concrete deck. I was wondering if this is normal to other people who have been using SAFE 12.
  15. structure567

    Create Report failure

    For one of my models, I tried running a report after running it and for some reason the report stops when its creating Picture 2.... Did anyone else have the same problem as I did?
  16. structure567

    design strips for unaligned columns

    Hello! So I'm trying to add design strips to columns that aren't aligned in a straight line. Is there any way of approaching this method that also includes the middle strip and the auto width function??

Part and Inventory Search