Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: johndaniel
  • Content: Threads
  • Order by date
  1. johndaniel

    User Written Model of a Generator in PSS/E

    Hi, I am trying to write a user written generator model of an energy storage in PSS/E 34.2, but I’m having trouble implementing it in FORTRAN. The model is not doing what it is suppose to do. I’m missing something in my model file. Does anybody have a sample user written generator model in PSS/E...
  2. johndaniel

    Space vectors Theory

    Hello Folks, Can somebody explain me the space vectors theory used in field orientation control of IM. How space vectors are obtained and how space vectors are different from space phasors? Thanks
  3. johndaniel

    Negative sequence directional element

    Hello Folks, I am new to the field of power system protection. I am working on a project where I have to calculate the values of 'Negative sequence directional element' for a radial system. I've successfully calculated the values of various parameters like pick up current, forward and reverse...
  4. johndaniel

    Protection zone selection

    Hello Folks, I am working on a project where I have to conduct protection and coordination studies of a loop system. Does anybody know how to select the zones of protection for a loop(mesh) system? Thanks
  5. johndaniel

    Directional protection scheme

    Hello folks, I am working on protection of a loop system, the system figure is attached. In this loop system, each section has two pilot protection relays. I've already achieved the protection of the system by using directional over current relay. Now in case of fault in any of the section we...
  6. johndaniel

    CT pase angle error.

    I have 3CTs which are passing current signals to SEL351S relay. When I am measuring the current phasors in relay they are showing following values: A B C N G I MAG (A) 6.604 6.734 7.331 0.000 13.759 I ANG (DEG) 174.51...
  7. johndaniel

    positive sequence element for balanced fault.

    Hello Folks, I want to know how positive directional element(F32P) is used to determine the direction of the fault current in SEL351S relay. I have a system where I have to develop a PSCAD model to determine the direction of all possible kind of fault in loop. I have successfully implemented...
  8. johndaniel

    Symmetrical faults.

    Hi folks I am working on a short project to determine the detection of symmetrical fault occurence in loop system. Does anybody have a idea about this thing? Thanks
  9. johndaniel

    Negative sequence directional element.

    Hello folks Can anybody give me good idea of negative sequence directional element in power system protection? and How to set the relays by calculating the parameters of network. Thanks
  10. johndaniel

    Forward and negative fault.

    Hey guys In negative sequence impedance directional element: what is the meaning of forward fault and negative fault?
  11. johndaniel

    Recloser control system

    Hello guys, I am working on distribution system where I have to develop a recloser control model in PSCAD. Although I have basic knowledge of recloser system but I couldnt find the control and operation of recloser system which I can emulate in PSCAD. Any suggestions would be helpful to me.
  12. johndaniel

    DC protection

    I am currently working on solid state transformer protection system design. I have to design dc protection of 400 Volt dc link but constraint is that I can not use circuit breaker for protection as DC circuit breaker is expensive. Any ideas and suggestions are welcome

Part and Inventory Search