  1. Kani77

    Contactor voltage rating for VFD DC bus

    Hi, I have two VFD 45kW, 600V, 3Phase, 60Hz. The DC bus of two VFDs are required to connect trough a contactor. What is the voltage rating of the contactor I should consider? Will 690V rated contactor suitable for this? Your comments is much appreciated. Thanks, Kani
  2. Kani77

    Braking Resistor Protection

    Hi, Do we need to protect the VFD braking resistor using fuses? If so how do I calculate the fuse rating? The braking resistor is 400W and 18Ohm, VFD output 600V, 3Phase, 60Hz. VFD rating is 45kW. I appreciate your feedback and help. Thanks, Kani
  3. Kani77

    1000V rated cable for 600/347V system

    Hi, Why we need to consider 1000V rated power cable for 600/347V Y system, solidly or resistance grounded. Your feed back is much appreciated. Tanks, Kani
  4. Kani77

    460V 60Hz motor on 480V 50Hz System

    Hi, Can I use 15HP 460V 60Hz motor on 480V 50Hz System? What are the formulas to calculate FLA of this motor at 480V 50Hz. Please provide a calculation example. Thanks, Kani
  5. Kani77

    Redundancy N-1 and N+1

    Hi, Can you please help me to understand the different between N+1 and N-1 redundancy. If the actual requirement is 75kW heater. What will be the combination for N-1 and N+1 redundancy system Thanks
  6. Kani77

    Stress cone on MV Tray cable

    Hi, Do wee need to use stress cones (Termination kit) for MV Tray cables 4.16kV and 23kV. Please share your knowledge and recommendation. thanks, Kani
  7. Kani77

    Ground resistance of horizontal conductor encased in concrete

    Hi!, I am looking for calculation formula for ground resistance of horizontal conductor encased in concrete. There is a formula in Ieee80-2000 for the vertical ground rod. Appreciate if some one help me. Thanks, Kani
  8. Kani77

    GPR rise in star grounded generator

    Hi, I am designing a ground grid for 1000kW, 3Phase+Neutral 277/480VAc 50Hz Generator. The Gen Neutral is star solidly grounded. What happen If the L-G fault at the generator. Do I need to calculate GPR rise as per IEEE 80 or only the touch and step voltage. The station is 400m x 400m. and the...