  1. DaniMP

    Anode in filters

    Hi everybody ! A quick question : My supplier of salted water filters has put the galvanic anodes in the top part of the filters. The entrance of the filters is by the side approximatively at 4/5 of the height of the filters, so the anodes won't be in the water, except during the washing (the...
  2. DaniMP

    Anode in filters

    Hi everybody ! A quick question : My supplier of salted water filters has put the galvanic anodes in the top part of the filters. The entrance of the filters is by the side approximatively at 4/5 of the height of the filters, so the anodes won't be in the water, except during the washing (the...
  3. DaniMP

    Baffle on a new tank

    Hello everybody ! I am designing a new oily water tank, and I want to have a compartment with a baffle so that the oil at the surface can flow from the main compartment (the tank) to the oil compartment. Are there any norm / constraint that I need to know ? For example, I have uploaded some...
  4. DaniMP

    Piping classes

    Hello everybody ! A quick question as I cannot figure it out by myself... One of my piping classes is for water, it is a carbon steel 600 lbs rating with a CA of 1,27 mm. Material is as API 5L grade B. My Temp / pressure couples are as follows : Pressure (bar) : 102 102 92.7 Temp (°C) ...
  5. DaniMP

    velocity at pump inlet

    Hello everybody ! A quick question regarding the velocity in the pump suction pipe : We have a water pump designed for 100 000 bbld. The water is @ atmospheric pressure and 20 - 80°C in the suction system. I would like to use a 12" pipe for suction, but the velocity would be of 2,5 m/s, and I...
  6. DaniMP

    Oil skimmer

    Hello ! I have a question for you : We are adding an oily water storage tank in our facilities, and I want to implement a skimming way of removing the oil phase that will form at the surface of my tank. Do you have any recommandation ? A floating skimmer inside the tank with an interface...
  7. DaniMP

    New nozzle on a steel storange tank

    Hi everybody ! This is my first post on this forum, so nice to meet you all :) I have a question regarding a water storange tank in use, operating at atmospheric pressure. We want to add 3 new nozzles on this equipment. Is the API 650 ruling this kind of modifications ? What would be the main...