Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SDETERS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: PEStruc
  • Content: Threads
  • Order by date
  1. PEStruc

    Retaining Wall Shear Key

    I'm Working on checking the sliding for a retaining structure that is in a high seismic zone and I have issue with the sliding. Tried to add shear key but thigs get worse because after adding the key, both passive and (active, surcharge and seismic earth pressure) increased, but the increases of...
  2. PEStruc

    Retaining Structure Subjected to Seismic

    Should we add the seismic forces due to own weight of seismic structure (Eh and Ev) to the dynamic seismic earth pressure force when we check the stability, especially if the own weight is significant? The used method for determining the dynamic seismic earth pressure is Mononobe-Okabe. Any good...
  3. PEStruc

    Design of Hollow Reinforced Concrete Beam that is subjected to Flexure

    Hello, Does anyone know a good reference and examples that explain how can a hollow reinforced concrete beam section(rectangular or circular)that is subjected to flexure and shear be designed? Does ACI address this kind of beam at all? Thanks!
  4. PEStruc

    Alignment Chart vs. Approximate values of effective length factor K

    Hi everyone, just trying to know when shall I use Alignment Chart vs. using the approximate values of effective length factor K shown in AICS table C-A-7.1? Appreciate your answer. Thanks,
  5. PEStruc

    Conventional MSE Wall Design Responsibility

    Hello Everyone, Just received a project where several types of wall will be used. One of the walls is conventional (standard) MSE. Would like to clarify, who shall provide the design of the concrete panel in terms of the thickness and reinforcement? Also, who should design the steel strip...
  6. PEStruc

    Ice Uplift Force on Piles

    Hi Everyone, I have a project in lake Michigan and it’s basically a marine dock fixed on piles in lake Michigan. I’m trying to calculate the uplift force on the piles due to the ice. The historical ice thickness is 30”, pile dia. is 12”, pile height above the lake bed is 14’ and it has an...

Part and Inventory Search