Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SDETERS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: engrnmc
  • Content: Threads
  • Order by date
  1. engrnmc

    AWWA D103 QUESTION

    i WOULD JUST LIKE TO inquire if the Impulsive acceleration and convective acceleration base on AWWA D103-09 is at service level or at strength level? specifically Ai = Sai I / 1.4Ri <-- Eq 14-16 Ac = Sac I / 1.4Rc <-- Eq 14-17 What does the 1.4 stands for? is it reducing the...
  2. engrnmc

    STAAD LOAD PATH

    Hi im new with STAAD, I'm currently designing a circular foundation to support a steel tank, I included the steel shell in my model and applied my hyrdostatic and hydrodynamic within the shell tank. i noticed that I'm not getting much reaction at the foundation due to the later forces applied...
  3. engrnmc

    Buttress Footing

    how do you design the footing on a buttress wall? would you be designing the slab as a oneway slab? negative moment towards the buttress wall? if so, hope could you compensate the negative moment that the wall will experience as my slabs moment will be travelling to the walls.
  4. engrnmc

    Combined footing quick question,

    Hi guys, i was trying to design a combined footing, and i notice that the reaction that im getting due to seismic is positive in one column and negative in the other ( due to the direction of the siesmic, in reverse if the direction is changed). since they have a couple reaction due to siesmic...
  5. engrnmc

    ACI 350-06 : Durability Factor quick question,

    Just a quick question, assuming that Durability factor (Sd) is already attained, Sd will be multiplied to the factored moment right and not the service moment? second, after multiplying the Durability factor to the factored moment, now you can design with the required reinforcement...
  6. engrnmc

    WALL DESIGN - OUT OF PLATE SHEAR

    hi just like to inquire some insight pertaining to wall out of plane shear. Based on ACI 318-08, out of plane shear shall be design same as slab and footing ( ACI318-08 11.9.1) where Vc is calculated based on the perimeter of it's critical section for shear, using STAAD plate analysis I would...
  7. engrnmc

    corbel design help

    Hi I am currently trying to design a a tower column for my suspension bridge overhanging to a platform, so to support the column I'm thinking of putting it on top of the corbel, but my worry is i might be missing something, or maybe there is a better approach in designing it. (DESIGN CODE : ACI)...