I need help on calculating liquid loading for a horizontal passive filter separator using natural gas as the product medium. natural Gas SG 0.58. Is there any empirical formula that governs such calculation . Any industry standard that help calculate these parameter?
Does the lube oil pump return piping necessarily be sloped to 2% when it goes from the process pump return ports to the lube oil tank reservoir. Does it need to have gravity flow to the reservoir, since the lube oil pump is continuously operating and has sufficient head to circulate the SAE 40...
Exceeding the design pressure as set pressure for the PSV for a ANSI 900(2220 psig) pressure system. What kind of problems can you face while in operation. following are the operating parameters.
Design factor for all fittings and piping is at 0.6 and materials adhere to API and ASME standards...
I need to understand when to use a weldolet connection vs threadolet on any pressure class piping ( ANSI 150, 600, 900, 1500).
So far I know that weldolets tend to have less stress concentrations than threadolets , but the question that's bugging me is why use threadolet if weldolets are so...
I have to pig a 24 inch crude line with a foam pig and I am unable to decide what size 90 deg elbow to use .
Should I choose 90 deg elbow of radius 1.5 D or 3D. I would also appreciate if you can refer me to a standard that has associated information about it as well.
Regards,