  1. Bloozntooz7868

    Negative Phase Sequence currents

    Searched the thread archive for this one, but didn't find what I was looking for. After showing someone how to calculate NPS currents from Generator data, they asked my a question that I had never even asked myself, and couldn't answer - What makes NPS currents rotate counter to the rotating...
  2. Bloozntooz7868

    NEMA/NFPA/NEC Standards for Thermal Overload Testing

    Quick one for the North American audience: Are there any standards (NEMA/NFPA/NEC or other) that specify that thermal overloads need to be current injection tested periodically, and/or after replacement? There are pro's and con's for testing them - pro's are obvious, but the con's are that they...
  3. Bloozntooz7868

    Multiple Ground Faults on Isolated Ground systems of mixed voltages

    I am having a bit of trouble getting my head round a problem regarding to systems of varying voltages running in Isolated Earth configuration. It is a floating vessel which comprises of a Topsides earthed system at 13.8kV, and feeders from the Switchboard go to the Marine side (Hull)...
  4. Bloozntooz7868

    Lenz's Law pictorial

    I need to roll out an electrical generation presentation to groups of Technicians to help underpin their understanding of generation principals. I was separately discussing with one of them about why Generators tend to slow down when load is applied, and how the Governor is increased to correct...
  5. Bloozntooz7868

    Resultant currents from Parallel Generators with different PF

    I am trying to make sense of currents I am seeing on 2 parallel incomers to a switchboard. We have a 480V Emergency Board with a main incomer from our grid (made up of 9 Turbine Generators), and a Diesel Generator (DG) incomer with a rated power of 1310kW. The intention is that if normal power...
  6. Bloozntooz7868

    Interpretation of NEC Code for Conduit Seals in Div 2 areas

    Sorry for the lengthy write up on a comparatively simple issue, but I want to provide all the info up front. I have tried to find this answered in other threads but found none that address this precise question. As a European, I need a little advice on the interpretation of the NEC code for...