  1. AntonioPerez

    Current asymmetry

    I've been asked for some grid quality requirements in a project. One of those parameters is current asymmetry. I'm trying to find any regulation or standard about it but I can't find. Does anyone know? Thanks in advance.
  2. AntonioPerez

    Converting TT to TNS earthing system to avoid untimely RCD tripping

    Hi all, An industrial facility owner who suffers from frecuent untimely RCDs tripping in his facility was adviced to convert the existing TT earthing system into TNS. We've been asked to quote the engineering project for that. I've never seen this done before but I guess it is not quite...
  3. AntonioPerez

    Insufficient breaking capacity

    I'm working on a project of an existing facility. There is a main switchboard with a molded case circuit breaker in the incoming whose breaking capacity is insufficient for the calculated short-circuit current. That incoming circuit will be properly protected in its beginning, by a new circuit...
  4. AntonioPerez

    Measure multiple polyline length

    Is there any way of getting the sum of the lengths of multiple polylines selected in Draftsight? I used to do it in AutoCAD with a LISP macro. Thanks in advance.
  5. AntonioPerez

    HVAC in substation while main power supply loss

    Hi, I was wondering if there is some standard that considers the situation of an HVAC system for a substation building during a main power supply loss. I'm participating in a project where ventilation was considered to be fed by a backup power supply but no air conditioning is posible while...
  6. AntonioPerez

    Distance between overhead power line and hazardous (ATEX) area

    I've been searching for any european standard that stablishes the required distance between overhead power line and hazardous (ATEX) area but I couldn`t find anything. In my case I have a 66 kV line over an outdoor propane/butane bottles storagement rack in Spain. I'd appreciate any help.
  7. AntonioPerez

    Short-circuit impedance tolerance

    IEC 60076-1 and other standards detail a concept of a tolerance in short-circuit impedance value. As I understand this tolerance must be taken into account during the process of manufacturing the transformer, as it is hard to define initialy the parameters to achieve the required impedance and...
  8. AntonioPerez

    Power transformer derating

    According to IEEE standard and others a derating factor must be applied to consider the effect of worse ambient and site conditions (altitude, ambient temperature) over an oil immersed power transfomer. As I understand, to assure the transformer won't suffer any damage, the transformer...
  9. AntonioPerez

    Protections included in VSD

    Hello, I'm designing an electrical facility to feed some motors (>75 kW) through VSD. We consider some ANSI proteccion functions in the switchgear (50, 51, 86) as if it was a feeder possition and we consider the specific motor protection functions in the engineered VSD. Some of the vendors in...
  10. AntonioPerez

    Copy to clipboard failed

    In some specific files I got the error "Copy to clipboard failed" when I try to copy any object, so I cant copy no object to another file. There should be some problema with those files. I cleaned them and audit them but it did't solve the problem. Any idea? Thanks.
  11. AntonioPerez

    Can't edit the snap point of a poligonal window

    In presentation mode I cant' edit the snap points of a poligonal window. When I try to click on a snap point the windows just get deselected so I can't find a way to edit the dimensions of the window. Any idea? Thanks
  12. AntonioPerez

    COM Surrogate error

    Sometimes when I open a file an when I close a file with draftsight I get the next error: "COM Surrogate stopped working". Draftsight works perfectly but it's a little anoying. Any idea?
  13. AntonioPerez

    How to insert an OLE object

    When you copy (Ctrl+C) an image in Windows and paste it (Ctrl+V) in AutoCAD you get an image inserted in your file, not an external reference, but an OLE object. When I open this file in DraftShight I can see the image and the properties menu says it is an "OLE (1)" type object but I don't know...
  14. AntonioPerez

    File doesn't remember the status of external reference layers

    I have a dwg file where I hide some layers in an asociated external reference and save the file. Everything normal up here but when I re-open the file I find that all hidden layers are visible again. I suspect the problem could be the file because I don't find the same error in other files. Thanks.
  15. AntonioPerez

    Pointer not visible in drawing area

    I can't see the pointer in the drawing area. I see it when it's over the toolbars. Any idea would be appreciated.
  16. AntonioPerez

    Empty attached images

    When I open some files in Drafsight I randomly can't see the attached images. I just can see the edge of the image. I can move, copy, scale, rotate it. Everything but see it in model space. When I go to paper space I can see the image perfectly. Any ideas? Thank you.

Part and Inventory Search