  1. trolex

    Minimum distance between welds API 650 (non-reinforcement nozzle and vertical fillet weld)

    I have been working on the design of a small API650 Tank and I'm having some issues with the spacing that between nozzles and welds. To be more specific, if we look at Figure 5.6 and 5.7.3 I have something close to the requirement for distance E. Also, NOTE 2, specifies the following: "Weld...
  2. trolex

    API 650 - Shell Manhole and Nozzel Inside Projection in a Vessel

    Dear All, I'm currently working on a project for a small API 650 tank (4 m3) and looking for nozzles and vessel design I'm kind of confused about the criteria on when to consider inside projection of nozzle and shell manholes on vessel body (shell) You can see here in this drawing that the...
  3. trolex

    Conduit System Requirement for Class I, Division 2 - General Doubts

    Hi Everyone, I'm currently developing a project that includes several similar modular units with several instrumentation and pumps package. The thing is that the electrical classification of the area where the equipment and instruments are to be installed is Class 1, Div 2, and installation...
  4. trolex

    PLC and HMI in a Explosion Proof Enclosure

    Hi everyone, Can someone tell me if there is a way to use a PLC+HMI in a NEMA 7 enclosure (explosion-proof enclosure)? Hazardous Location is Class I, Division 2, Group D. I have read many posts but not sure they usually suggest using a purge system which is not my case since I don't have the...
  5. trolex

    Class I, Division 2, rated accesories inside of typical NEMA 4X enclosure

    Hi eveyone, I would like to receive some advice on a particular issue I have with a Control Panel . I need to provide a Control Panel with a PLC and HMI in an enclosure. The point is that it is for a Hazardous Location: Class I, Division 2, Group D. If it's possible to use a NEMA 4X...
  6. trolex

    Several type of joints using just one WPS

    Hi everyone, I have some doubts that I would like to receive some help. We've imported an oil-water separator tank which is constructed based on UL 58 (double wall tank for underground installation)for our customer. I requested our supplier to provide all quality documentation for our customer...
  7. trolex

    Sodium Metabisulfite Plant doubts / a lot of them

    Hi everyone, I apologizes in advance because this post will be too long.. Really sorry for that. I have some problems in the design of a Sodium Metabisulfite plant for a gold mine. I'll explain all the content and basically is as follow: ENVIROMENTAL CONDITIONS Humidity is around 70-90%...
  8. trolex

    Doubts about Sodium Metabisulfite and its reaction with water

    Hi everyone, I'm currently working on a mining project for a gold mine that involves the usage of Sodium Metabisulfite. They will mix Sodium Metabisulfite with water to create a first solution at 30% in a make up tank (preparation tank + mixer/stirrer) and after that will be deposited in a...