  1. 186skier

    Moment equations based on lateral movement of a rigid body

    What is equation for moment created from a lateral movement of a rigid body. I have attached example from STERM based on a fixed-Fixed condition = M =6EI&/H^2 and I believe it is 4EI&/H^2 at pinned end and 2EI&/H^2 and fixed end. See attached for example and point me in the right direction of...
  2. 186skier

    Mean Roof Height used for Components and Claddding -ASCE 7-05 -SImplified Procedure

    When designing a window wall of 12'-0" at the base of the building for components and cladding -Simplified per ASCE 7-05, would I use Lambda = 1.21 for H<15', or would I use Lambda = 1.29 for H= 20'. (Page 40 of the ASCE 7-05 FIG 6-2). The actual mean roof height is 18'-0"(+-)It seems like I...
  3. 186skier

    What is minimum cover for cast on site Tilt up Panels on site?

    The UBC 97 clearly states that it is 1" for tilt up walls But in the current ACI-318-11, it seems to be vague, is it 3/4"? The walls are cast on site and not at a plant. Also where is this in the CBC-2013 or ACI 318-11?