Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: engjg
  • Content: Threads
  • Order by date
  1. engjg

    Dynamic Load Allowance (IM) | AASHTO | Minimum Vehicle Design Speed

    Is there a minimum vehicle design speed where AASHTO requires the dynamic load allowance be considered, or are they silent to it and so conservatively it would need to apply at all design speeds? Application is design of access hatch for underground vault in sidewalk that can be driven onto at...
  2. engjg

    Stretcher CMU - advantages & fully grouting

    It appears there is an industry preference of "stretcher" block CMU over a standard ended unit in the field of the wall. Can someone provide insight into the advantages of using "stretcher" block. Also, Is it possible to fully grout walls constructed using "stretcher" block?
  3. engjg

    Wood stud deflection - FBC - wind

    In the context of: exterior wood wall stud with typical window components FBC 2023 code (IBC 2021 with amendments) interior gypsum wall board flexible exterior finishes What is correct FBC interpretation/application for deflection ratio and wind load factor?: 0.42xW and L/120 (Table 1604.3...
  4. engjg

    2x tongue & groove decking diaphragm nailing IBC & SPDWS

    IBC calls for (1) 16d face nail and (1) 16d toe nail for 2x lumber decking. NDS SPDWS call for (2) 16d nails at intermediate supports to substantiate a diaphragm for horizontally sheathed lumber decking. Does the toe nail qualify as one of the nails for the diaphragm?
  5. engjg

    Extending slab on grade contraction joint spacing with reinforcement

    ACI 360-10 provides recommendations for unreinforced slabs on grade contraction joint spacing of 24 to 36 times thickness of slab ACI 360-10 8.3 speaks to 0.5% reinforcement to eliminate the need for contraction joints ACI 360-10 8.1 notes benefits of reinforcement allow for "use of longer...
  6. engjg

    masonry shearwall net area for shear

    In evaluation of a masonry shearwall should one use the horizontal section properties (vertically spanning) or vertical section properties (horizontally spanning)?
  7. engjg

    Precast Concrete Wall Panel Sliding Friction at Base

    Regarding Tilt-up concrete wall construction and in plane shear resistance at the wall to footing interface I note ACI 551_2R-15 comments: "The coefficient of friction for factored sliding resistance between the panel bottom and the footing can usually be taken as 0.6. Supplemental positive...
  8. engjg

    Wave Loads - breaking vs. non-breaking, ASCE 7 vs. Goda, finite wall height

    I am trying to develop wave loads for a structure where I expect the wave(assumed to be depth limited) will over top the structure. Using the ASCE 7 equations and just neglecting the portion of the pressure diagram where it will be overtopped I am coming up with load much higher than...
  9. engjg

    Progressive Collapse - One Story

    Is progressive collapse still a consideration for one story structures. I am working with ASCE 7 and the UFC codes. Obviously from a gravity perspective if a column is knocked out that portion of the roof comes down. But how about lateral systems does progressive extend to redundant lateral...
  10. engjg

    PY lateral drilled shaft analysis P-Multiplier group effect vs. depth

    I see aashto provides guidance on p-multipliers for a py lateral pile/drilled shaft analysis group effect. I am using LPile and have two questions regarding the application of this: 1. LPile allows for varying the p-multiplier based on depth below pile head; does anyone have guidance on how you...
  11. engjg

    retaining wall with soil key - key placement and coefficient of friction soil-soil vs soil-concrete

    When you add a soil key to increase sliding resistance my understanding is that you can consider soil on soil tan(phi) friction as opposed to soil on concrete tan(2/3*phi) since the failure plane will be through the soil. Can anyone provide a reference that supports this? Also under this...
  12. engjg

    ACI 318-14 Members not designated as part of the seismic-force-resisting system

    Trying to decipher tie requirements for a gravity only column in a SDC D structure. It seems regardless of whether you evaluate the design displacement or not they send you to 18.7.6 which requires shear force calculated from Mpr? If so it seems the tie requirements are almost the same as it if...
  13. engjg

    ACI concrete exposure and reinforcement cover in coastal environments

    In dealing with a coastal structure, at what proximity to the shoreline to you start considering it having atmospheric exposure? How about if your on an island but a 1-2 miles or two from the shoreline? At what point are you C1 or C2 concrete exposure? At what point do you need increased...
  14. engjg

    P big delta with pin base design assumption (brace frame, moment frame, tilt-up)

    Interested in other's thoughts on P big delta affect when designing with a pin base design assumption. With a pin base idealization, p big delta doesn't theoretically exist, and drift of structure would just result in a shear thrust at the base, no? But since pin idealizations usually always...
  15. engjg

    ASCE 7-16 Wind Topographic Effect Debate - See Graphic Attachment

    Do you think the top profile on the attached meets the intent of ASCE 7-16 §26.8.1.2? The bottom profile is my interpretation of the ASCE 7-16 commentary section, by this interpretation the site location in the top profile would need to be 280 ft x 2 + 280 ft = 840 ft and it is only 561 ft so it...
  16. engjg

    ACI "Column Shear Cap" vs "Column Capital"

    In looking at ACI 318-14 I see where Shear Caps are addressed in section 8.2.5 where it is required they extend a distance from the column face equal or greater than their depth below. I don't see where column capitals are addressed. I take the distinction between a shear cap vs. capital is one...
  17. engjg

    Flat Plate Slab Roof: Sloped Cement Topping - Adhesion, Effect on Stiffness, Uplift

    I have a flat plate conventionally reinforced concrete slab roof. Contractor wants to use a sand cement slopped topping with either a torch down or liquid applied roof covering. I am pondering the following about this: 1. I can account for an average or max additional dead load for the...
  18. engjg

    Warehouse Diaphgragm Expansion Joint - Chord Continuity

    Warehouse roof framed with steel joists and joist girders, long span of roof diaphragm is 520'. Considering expansion joint. I see details with two rows of columns that transfer shear but how do you deal with diaphragm chord forces? Also in looking at AISC DG 7 regarding recommendations on when...
  19. engjg

    AASHTO vs ACI Effective shear depth differences

    Looking for background information on difference in the effective shear depth definition between aashto and aci codes. I note aashto limits d to 0.9de. I want to know what is the reasoning behind this reduction?
  20. engjg

    Special Masonry Shearwall - Joint Reinforcement

    Is it permissible under IBC 2015/ACI 530-13 to use joint reinforcement to satisfy the horizontal reinforcement ratio of special masonry shearwalls? I see in the 7th ed of the Reinforced Masonry Engineering Handbook they show an example doing this but do address how this satisfied the requirement...

Part and Inventory Search