I am performing a response spectra calculation of a component composed of Beam44 (legacy model) and Shell63 elements. Looking at the stress intensity using PLESOL and PLNSOL results in a much larger (almost 2x) max stress intensity then when I sort an ETABLE containing stress intensity. I am...