Am i interpreting Division 2, part 5 correctly that when using bolts in a cyclic operation, the maximum number of cycles is 1E6? I get this from table 3-F.9. The values in 3-F.8 (at the 13.5 KSI and 5.3 KSI limits) also confirm this.
Does this mean I can't have any bolted connections if my...
When doing an analysis per Div 2, part 5, is it acceptable to do the FEA on each component separately or does it need to be done on the entire assembly at once?
For instance, say I have a pipe with two bolted on blind flanges on either end. Can I perform FEA on the pipe, flanges, and bolts...
I'm having a couple of issues with this part of the code.
Equation 5-C.5, Tp is asking you to add a function (T) with a scalar. Additionally, they're asking you to add a temperature (Tavg) with a Temp per inch value (2Tb/t). Am i missing something?
Any clarification with this portion of the...
I'm trying to create a calculation package for a pressure vessel that does not have a standard shape (i.e. not a shell, hemisphere, conical, etc.) Is there a way to perform this calculation under Division 1 rules? For instance, if I can fit a hemisphere entirely inside my part, can I design it...
Does anyone know/have a source for deriving the formulas for area reinforcement?
Are the limits of reinforcement (UG-40(b) & UG-40(c)) calculations already taken into account in the formulas given?
thanks,