hi every one,
During welding St.St 347 thk45 mm Dia./16inch of transfer line between ammonia converter and waste heat boiler we observed cracks in root toes.
we use ER347Si for root passes and E347-15 for filling passes- and N2 as purging gas .
the specification of line are
-ammonia synthise gas...