Hi,
For a seawater storage tank i am using a sacrificial Aluminium anodes system to protect the internal submerged surface. Is it normal that when i calculate anode life the result is about 2 years (depending on the dimension of the chosen anodes).
according to the calculation formulas and due...
Hi,
For a short length of buried pipeline, I will use a galvanic cathodic protection system by connecting a Mg anodes. Is it necessary to place an isolating kit on the extremity of the pipe or this is not required because it is not a ICCP system.
Hi,
For the cathodic protection design of 200 Km of pipeline i used the the following formula to calculate the protected length: L_max=Acosh[(Es)/(El)]/α
the L calculated is the total protected length or the length of protection in one direction from the draining point???
meaning if my draining...
Hi,
I will design a cathodic protection system for an already existing tank with a 100m of diameter, under the tank at 500mm depth a layer of PE sheet is spread entirely
so - because it's not a new tank i can't use the grid anode under the tank
- because of the PE layer I can't use the beep...
Hi,
I would like to know how we can choose the best type of groundbed for the design of cathodic protection system for buried pipeline ( conventional, distributed or deep groundbed).
Thanks
Hi!
Normaly,the waard model is for pipeline in wet conditions, but Is it possible to use it for the calculation of the corrosion allowance for a tank or a scrubber for exemple
Thank you