Hi Everyone,
Please refer the attached file.
Can anyone suggest me how to design a davit arrangement for a pad type nozzle with blind flange on bottom of dish head?
The nozzle mark N2 can be shifted to maximum distance of 165mm from centre.
Awaiting a prompt response.
Regards,
Balaji...
Hi Everyone,
I have one query regarding radiography marking on ASME U stamped vessels.
As per client requirement Category A (Long seam) & Category B (Cir seam) of shell must be spot radiographed, i.e E =0.85.
But Category A joint of dish with seams must be fully radiographed, i.e E =1.
Kindly...
I want to perform a calculation for a Flange with External loads acting on it.Find the below details:
Size = 3"150#
MAWP = 244.322 psi
Design Temperature =181degF
Flange material = SA 105
Bolting Material= SA 193M Gr.B7
Corrosion Allowance= 3mm
As per new Interpretation (BPV VIII-1-16-85) we...