  1. SteynvW

    Importance Level and Steel Construction Category

    I have a scenario where I have specified a Construction Category 3 according to AS5131-2016. The contractor is obviously not happy. The structure overall is an importance level 4 (Hospital) structure but in our project (internal fit-out) wall stiffeners are added, and or some steel arrangement...
  2. SteynvW

    Hooped Truss

    Busy doing some small alterations to a building, saw these trusses. A mechanical engineer's dream. It is a interesting use of Vierendeel Action! https://files.engineering.com/getfile.aspx?folder=2b809268-0dd2-44a2-a20b-89c3347a407c&file=MicrosoftTeams-image_(3).png
  3. SteynvW

    Ko At Rest Factor

    Good Day Something interesting came across my desk today, the geotechnical report of an existing building has a Ko factor (long term) of 1,2 for at-rest lateral soil pressure. Is this not supposed to be a maximum of 1? The site is underlain by clay, can the Ko factor be larger than 1 due to...
  4. SteynvW

    Vertical Crank in Suspended Slab

    Does anyone have a reference for when it is permissible not to have special detailing at a vertical crank in a slab? My slope is 1:18 and detailing it like a big change in angle feels like a...
  5. SteynvW

    Portal Frame Vertical Deflection

    Hi All I am aware this has come up in previous discussions, my intuition is just fighting with all the literature i am finding. I Have a portal frame with 35m clear span and 6,5m eaves height. I have calculated the deflection as 134mm, this is including nominal rotation stiffness at the base...
  6. SteynvW

    Sydney Apartments Cracking

    https://www.abc.net.au/news/2021-06-17/toplace-development-residents-blocked-castle-hill-skyview/100223462 Any idea what those plates would help for? Sliding Joint with the plates bending helping with differential movement across expansion joint?
  7. SteynvW

    Pony Truss Bridge First Mode of Buckling

    Hi All When doing a elastic buckling analysis of a pony truss my second mode of buckling is the expected sinusoidal shape as expected. I could then back calculate the effective length and design the top chord appropriately. However, my first mode of buckling causes my structure to rotate...
  8. SteynvW

    Concrete Moment Connection Detailing

    Hi All Regarding the reinforcing detailing of a concrete moment connection. Situation A is under gravity loads with the top of beam and the outside of the column in tension. Now with lateral loading the situation reverses on one side of the building, does one lap the beam reinforcement as...
  9. SteynvW

    Concrete Retaining Walls on Piles

    Hi All We have this detail of retaining wall on piles floating around in our office. It is a cantilever retaining wall that is built on a concrete base with beams on the edges. The moment from the wall is transferred to the beams trough a coupling moment. These beams then span to a pile cap...
  10. SteynvW

    Column Beam Concrete Connection

    Hi All In the attached picture is a concrete column and beam connection. For the beam design moments at the end will be ignored and the beam designed as a pinned support at the column. For the lateral stability, can the negative moment that will be generated/developed by the top reinforcing...
  11. SteynvW

    Cold Formed Section- Global Buckling

    Hi All We were recently assigned to evaluate an old existing warehouse and to establish if solar panels can be added to the rough. Now the purlins are an odd size Z-shape where our design code does not have tables for, so we dived into the abyss that is cold formed steel. Our code is based on...
  12. SteynvW

    Cold Formed Handbook

    Hi All Is "Design of Cold-Formed Steel Structures : To Australian/New Zealand Standard As/nzs 4600 2005" by GJ Hancock a good reference book to have for cold formed member design? Does it include examples? Kind regards
  13. SteynvW

    Mesh Check - Lion Enclosure

    Hi All We are currently designing a Carnivore Enclosure at a Veterinary Hospital. We have concrete walls on 3 sides and a steel ceiling and steel closure on the 4th side. The ceiling has a hollow section frame with steel mesh in between. The architect specd a 3mm welded mesh with 50x25mm...
  14. SteynvW

    Structural Fees

    Hi All How does the structural fees of projects compare to fees of the quantity surveyor on the professional team? Does the QS normally get more that the civil and structural engineer? Lately in my area of the world if you do work for a private developer, they will have a fixed sum for...
  15. SteynvW

    Active Anchor Earth Pressure

    Hi All I currently have a situation where we are building next to a railway with a retaining wall between us (our property on the higher level). They require us to compile a report of what our structural effect/loadings it will add to the retaining wall. I have calculated this according to the...
  16. SteynvW

    ACI Journal Free Standing Staircases

    Hi All Does anyone maybe a link/soft-copy for ACI Journal from 1 May 1966 on Freestanding Staircases? Kind regards
  17. SteynvW

    STRAP-USER MANUAL

    Hi All Is anyone here using strap? Or more specifically has a link to examples or tutorials? I have been using it for quite a while but only modeled slabs and basic structures. Kind regards
  18. SteynvW

    High-rise Lateral Resisting Systems

    Hi All Can someone prescribe literature for high rise lateral load resisting systems in terms of analysis and design? Kind regards
  19. SteynvW

    Helical Stairs

    Hi All I have to design helical stairs, I have looked at previous threads concerning the topic and my own google research and all the fingers point to "Design Charts for helical stairs with fixed supports" by A.R. Cusens & S. Santathadaporn. I just cant seem to find it on the net. Does...
  20. SteynvW

    Preffered Beam Detailing

    Hi All We had a discussion in our office and I would like to know you preffered method. When to beams connect over a column: 1. Secondary beam top reinforcing is placed lower througout beam under primary beam top reinforcing and designed with the reduced depth. 2. Secondary beam top...