  1. RMERMP

    FireProtection for Cold Storage.

    Good day! may i ask if there is a need of Fire Protection (sprinkler system) for a cold storage? i jus cant find 1 code in NFPA 13 on this one thanks.
  2. RMERMP

    Sprinkler number.

    What if i have an elongated room. with an area of 517 sq.ft. its classified as light hazard. in light hazard the sprinkler have 225 sq.ft of protection so, 517/225 = 2.297 use: 3 sprinkler in the room. but since its elongated should i use 6 sprinkler to protect the room? the dimension of the...
  3. RMERMP

    Space between the roof and the ceiling

    i have a question, is it required to put sprinklers below the roof? the situation will be an existing warehouse will be converted to an office building. there is a space [highlight #204A87]between the roof and the ceiling (just like an attic). thanks,
  4. RMERMP

    Heat Remove by Ventilation.

    Good day! i have a situation that seems very easy for you guys. how can i reduce ambient temperature inside a room using ventilation system alone. For example, my target ambient temperature drop is (-5 degrees Celsius) in a closed room using outside air. Example data: Outside air: 40 degrees...
  5. RMERMP

    Lighting fixture and sprinkler heads

    Im trying hard to find a code that states that lighting fixture is considered as an obstruction to our sprinkler. Is there any code state that? Please direct me.thanks
  6. RMERMP

    Chilled water pipe sizing.

    Can someone please confirm if im using the correct way of sizing up a chilled water pipe? the total TR of all the fan coil unit is 40 TR. 40TRx 2.4GPM = 96GPM then i input it into the sizer it said im should us3 80mm size pipe. my other question is, how can i size up the pipes in their max...
  7. RMERMP

    Electrical room exhaust fan

    what air change can i use to ventilate a electrical rooms where 7 panel boards are installed inside? i was able to find 4-6 air change. can i use this air change? thanks
  8. RMERMP

    Bellmouth Return sizing (ceiling return air system)

    can anyone teach me how to size the bellmouth if i have 20000cfm supply air? i read the size of bellmouth should be double the size of the main return duct so that the return air will have low velocity in the ceiling. thanks
  9. RMERMP

    OFFICE BUILDING

    I'm trying to find a minimum area requirement of office occupancy that need to be protected by automatic sprinkler system? can anyone direct me to a code regarding this? im reading IFC now but i cant find the requirements in Group B occupancy. for reference purposes only. thanks
  10. RMERMP

    Server Racks

    i found myself calculating for the heat dissipation of server racks. they have 12 server rack with 3000w per racks, that's 36kW total load of racks. how can i size up the air conditioning system of the server room. (the server room has only 12racks the UPS is separated to the adjacent EE room...
  11. RMERMP

    Fire Hydrant

    i have a situation where the school that im designing fire protection wet system standpipe have a large space in the middle (courtyard, where the children play after school) im wondering if i can put fire hydrant in the courtyard since the buildings to be protected surround the courtyard. thanks
  12. RMERMP

    FM 200

    Good day! I'm having difficulty on computing the total lbs i need for a 2080 cubic feet server room with design concentration of 60 Fahrenheit. i just need to identify how many tank shall i reflect in my plan. thanks in advance.
  13. RMERMP

    Air space for tank

    Good day! Can someone direct me to code about minimum air space for tanks. thank you.
  14. RMERMP

    UPS ROOM AND TRANSFORMER ROOM

    what is the safe air changes in this kind of rooms for exhaust? thanks.
  15. RMERMP

    Pipe Sleeve

    Goody day, i have a situation concerning pipe sleeves. can the size of the pipe sleeve depends on the size of flange connection? i have 150mm pipe near a wall the consultant told me that the size of the pipe sleeve should be bigger than the flange so that the pipe can be pull out easily for...
  16. RMERMP

    Flange connection

    Good day, can you please direct me where can i read code about installation of flange connection. thanks
  17. RMERMP

    Server room

    i was estimating the heat load in the server room. 7500w per rack but i know its electrical unit not cooling load. can i covert 7500w to cooling load for me to determine the size of AC ill be using? thanks.
  18. RMERMP

    Using two sprinkler riser

    Good day, i have a question regarding risers, im designing a school having very large total area. it has a open field in the middle so the classroom are located at side of the oval field. the owner whats to have sprinkler protection throughout the campus. i proposed two risers since the area is...
  19. RMERMP

    Exhaust for comfort rooms

    is it right and economical having 1 exhaust fan ducted for two comfort rooms?
  20. RMERMP

    System Protection Area Limitations.

    8.2 System Protection Area Limitations. (4) Storage—High-piled storage (as defined in 3.9.1.17) and storage covered by other NFPA standards — 40,000 ft2(3716 m2) any exception for this code? when you exceed to 3716m2 do we really need 2 risers? for example the warehouse area is 3721 m2? it...