Hello,
Last month, my company upgraded to TC 10.1.6 20160315, due to requirement to work with NX 11 from our customer.
Ever since the upgrade, we experienced few bugs, which we resolved most of them.
One serious bug which is not yet resolved, is the incorrect display of stylesheets for items...
Hello,
Recently we updated to NX 10.0.2 (it was 10.0.1 before), and now when we create new item in NX integration, we suddenly get a new "required" field called "partno". We also noticed that the item id is now referred as DB_PART_NO (which is not like it was before)
This field can be...
Hi.
I've been looking for a way to make a "undefined corner symbol" like in ISO 13715
Example can be seen here:
http://www.en.technisches-zeichnen.net/technical-drawing/basics-02/edge-informatinos.php
Thank you in advance.
Hello,
When we open excel file from TC (by double-click on xlsx dataset), the computer freeze for long time, sometimes even needs restart.
It usually happens when there's a "unmanaged" excel process running, but sometimes also when there is no excel process at all.
The local integration...
Hi.
We recently get NX files from Daimler.
For example, one delivery has the following files:
A1234.prt (assembly)
A1234_1.jt (geometry)
If we open the assembly on the Daimler Supplier Package, it creates a file called A1234_i_jt.prt, and it appears in the assembly navigator, but not on the...
Hi.
I'm not sure where is the right place for the question - here or in the NX forum...
We recently get NX files from Daimler.
For example, one delivery has the following files:
A1234.prt (assembly)
A1234_1.jt (geometry)
If we open the assembly on the Daimler Supplier Package, it creates a...
Hello,
I have to handle 3 large assemblies, located on the same folder (actually on teamcenter, but doesn't matter).
They have a lot of common components, but some are specific. These are different variations of the same design.
Is there any "fast" way for creating a "common" assembly for all...
Hello,
Is there any method for checking out an NX dataset, for working offline, i.e. when not connected to server overnight, and once connecting back, to check in on the server?
Thank you
Hello.
Is there any way to manually "release" the CATIA_Integration license from FlexLM?
The problem is that occasionally, designers close the CATIA software, but the Integration license is still borrowed, until the Administrator kicks them from their active session.
Other option is a complete...
Hello.
On my organization we work with NX9 and NX10.
Each desiner has a USB Key (Hardware key) linkeded to license file and Sentinel driver.
In addition we have few floating licenses on FlexLM server.
Is there any way to set an "automatic" sequence for loading NX with Sentinel and if it fails...