Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MhFitri
  • Content: Threads
  • Order by date
  1. MhFitri

    Manhole size per Asme VIII

    Hi guys, I`m designing a atmospheric/low pressure horizontal tank with opening for manhole of 600mm and i use 24" Flange for the manhole flange and blind cover. The thing is, client and fabrication team asking to reduce the thickness and number of bolts of the flange. The reason is because the...
  2. MhFitri

    New Laptop for Designing

    Hi guys, I would like to ask for opinions for a new laptop to do 3D design and simulation. I know that its better to have a desktop, but i`m currently do now stay at one place to do my job, thus my boss asking me to get a good laptop for myself to get my work done. Below are the specs: Option...
  3. MhFitri

    Storage Tank by PV Elite

    Hi guys, I`m designing a flat head storage by atmospheric pressure using PV Elite software and report the design data. However, i`ve been asked to include the foundation loading table, force and moment in all direction Fx, Fy Fz, Mx, My and Mz. I`ve been informed that PV Elite does not give the...
  4. MhFitri

    Class 5000 ASME B16.5 Flange

    Hi guys, Is there any standard that gives the dimension of Flanges of Class 5000# ASME B16.5 that i can refer to? I usually works with 150# and i have the B16.5 Standard to refer the dimension. Maybe my copy is the old one, but the it only cover until class 2500. Google search gives me the API...
  5. MhFitri

    Applying load per meter cube

    Hi guys, How do i actually apply load per meter cube on a U shape flat surface? I`m trying to model a platform with 4w x 8d x 1h meter overall dimension, including stair, and i`ve been asked to apply a 200kg/m3 to verify whether the design is adequate. This is my first time being asked to apply...
  6. MhFitri

    Tank per API 650

    Hi guys, I wish to create an analysis for a blending tank as per API 650. The tank having a cylindrical section of 1800mm H and I.D with a conical section at bottom from 1800mm to 60.3mm nozzle opening. However, after going trough the API 650 12 Ed, the standard does not give detail...

Part and Inventory Search