  1. Sruthish

    Pressure Drop across the Mist Eliminator Vessel with Internal Cyclone Bundles.

    Hi All, We are supplying Mist Eliminator vessels to our Client with Cyclone bundle internals. The Flow parameters are given below. Flow Rates Max: 1471 m3/hr Normal: 1421 m3/hr Min: 1371 m3/hr Operating Pressures Max: 332 PSI(g) Normal: 323 PSI(g) Min: 313 PSI(g) Operating Temperature...
  2. Sruthish

    [img http://res.cloudinary.com/engi

    I have seen one of the datasheet for cryogenic vessel which specifying the vessel shall be designed for Allowable temperatures of -196 Deg C as the minimum and -20 deg C as the maximum. I beleive that this implies the vessel can withstand with a lowest temperatue of -196 deg.C and maximum...
  3. Sruthish

    Cryogenic Vessel Design Specification

    I have seen one of the datasheet for cryogenic vessel which specifying the vessel shall be designed for Allowable temperatures of -196 Deg C as the minimum and -20 deg C as the maximum. I beleive that this implies the vessel can withstand with a lowest temperatue of -196 deg.C and maximum...