  1. Josep Maria Perdigo

    Electric boiler according to ASME VIII-1

    Can there be a very small completed electric boiler stamped only with U-stamp and the letters UB (special service), that is, without the E-stamp (ASME I)?
  2. Josep Maria Perdigo

    Fig UG-34 sketch(b-2): Welding a forged flat head to shell, without doing Tension Test Specimen

    Dear colleagues I have designed a forged flat head according to fig. UG-34 sketch (b-2) / UG-34(d)(3). The length of flange is quite large, so that the flange-shell weld is away from the corner (radius r) and from the hub (tapered zone). See attached figure, with dimensions. The question I...
  3. Josep Maria Perdigo

    Flat head UG-34(d)(1), (2) or (3): forge vs cold formed

    Dear colleagues: Flat heads according to UG-34 (d) (1), (2) and (3) shall be “forged”. Here “forged” means a forming process that implies heating, or else, the flat head may be produced by cold forming according to UG-79?
  4. Josep Maria Perdigo

    Application temperature limits of SS 904L

    Dear forum members, I was surprised that the SA-312 grade 904L pipe has an application limit of 371°C (700°F) for ASME VIII-1, while in ASME B31.3 the limit drops to 260°C (500°F). Does anyone know the reason for this big difference?
  5. Josep Maria Perdigo

    EN 13445-3, 17: Simplified fatigue assesment

    In EN 13445-3: 2014 tables 17-2 and 17.3 are missing. I think this is an editing erratum. I will continue to use the tables of EN 13445-3: 2009.
  6. Josep Maria Perdigo

    RePad in two pieces

    In the framework of ASME VIII-1, can I make a RePad in two pieces? (See attached figure) The welds between the two parts would be butt. There would be a ventilation hole in each part. Can the longitudinal welds be considered as category A and the circumferential category B as per Fig UW-3...
  7. Josep Maria Perdigo

    Boiler room

    The Spanish regulation of boilers (RD 2060/2008 ITC EP-1) establishes that the boiler room must have reinforced concrete walls of 20 cm thickness. Doors can not exceed 1.2 x 2.1 m. The roof has to be of light material. The objective is to protect the people outside the room, in case of boiler...
  8. Josep Maria Perdigo

    ASME PTB-4, E.4.12.2 Reinforced Vessel of Rectangular Section: there is an inconsistency in data

    In ASME PTB-4, example E.4.12.2 - Reinforced vessel of Rectangular Cross Section, there is an inconsistency in the stiffener data: The moment of inertia is not consistent with the height and area of the rectangular section. Let's see: - Stiffener shape: rectangular - Stiffener cross sectional...