Hi all,
Just looking for peoples thoughts/opinions on the following.
A project we are involved in calls up in the Spec.
"surface finishes shall be in accordance with AS3610....."
I take this as only been applicable to formed surfaces as that is within the scope of AS3610.
The builder however...
I've just measured onsite a 125x50 RHS section. Does anyone have any information on these as it must be a section size before my time or simply a rare one, maybe imported?
My approach at present would be to assume grade 250, or is this too conservative.
I'm in Western Australia
Cheers
Toby
Hi all,
I am just starting on a new 3 Storey project.
Office and parking at ground with 2 levels of Residential over.
I am designing the floor and its supports over the parking for an Fire resistance level of 120/120/120 (Structural adequacy/Integrity/insulation)
I just received a drawing of...
Hi all,
Anyone have any data on historic I-beam shapes use in Australia (specifically WA). I am assessing an existing building which has a 360 deep I-beam with a flange width of 140mm which doesn't match todays profiles. Building is circa 1950-60. I'm specifically chasing the steel properties...
Hi all,
I'm looking at a steel structure designed and constructed in 1985 (AS1250 I believe) and was hoping someone may be able to help us out with steel grades used in that era in Australia. Specifically I'm looking at Equal Angle sections and bolts
Thanks in advance
Toby
Hi all,
I have a query regarding the appropriate selection of pressure coefficients from Table C2 in AS/NZS1170.2 APP C. (attached)
Do you sequentially take the roof pressure from the windward wall. I would do this, but
For example - 0 degree angle of attack
2Span Sawtooth Roof -- are the roof...
Anyone got experience with these tie-downs? or something similiar?. I'm starting to see Prefab timber suppliers using these.
They are basically a screw fixed down through timber top plate into the end grain of the timber stud. I know most timber codes provide some sort of capacity reduction for...
Hi all,
Re-posting this from last year.
--Does anyone know if the Sds "design 5% damped spectral acceleration parameter at short periods..." (from ASCE7) has an equivalent in AS1170.4?
Assuming it is equivalent to KpZCh(T) where Ch(T) is taken at short periods (i.e. at its maximum value) ASCE7...
Hi all,
Have got a project that is a Single Storey Portal frame shed with Tilt-up Cladding panels. Now the spacing of the Portal frames is approx. 6m and the Panel height to eaves is approx. 10m. Such large panels as one may pose an issue with craneage, so I am considering splitting the panels...
Hi all,
I'm curious about the AISC341-16 provisions concerning Ordinary Concentric Braced frames "OCB" (I'm in Australia so don't know the standard that well). It states that the slenderness of the braces in a "V" type configuration must satisfy
Lc/r<4sqrt(E/Fy)
I understand this seems have the...
Hi all,
I have a job in the works with tilt panel walls (basically a single storey big box) with a timber ply ceiling. I am happy to structurally use this ply ceiling as a diaphragm, yet am not sure if I can comply with the Building Code of Australia (BCA) regulations that stipulates the panels...
Hi all,
A client has proposed to use tilt panel cladding on the boundary (for fire reg's) attached to their typical Cold Formed Portal framed Shed. I personally don't think it is a good idea, I only have experience with using tilt panel cladding on Hot-rolled Steel Portal frame building(s) - or...
Re-posting here to hopefully get more traffic...
Hi all,
Does anyone know if the Sds "design 5% damped spectral acceleration parameter at short periods..." has an equivalent in AS1170.4?
Assuming it is equivalent to KpZCh(T) where Ch(T) is taken at short periods (i.e. at its maximum value)...
Hi all,
Does anyone know if the Sds "design 5% damped spectral acceleration parameter at short periods..." has an equivalent in AS1170.4?
Assuming it is equivalent to KpZCh(T) where Ch(T) is taken at short periods (i.e. at its maximum value) ASCE7 and AS1170.4 don't compare well in regards to...
Hi all,
Anyone have information regarding magnitude of loads to consider in the assessment of structures to support "trapezes" and similar Circus activities ("Silks etc...). I have a client wishing hang a trapeze off an existing roof structure. I am having trouble pinning down appropriate...
Hoping to get others thoughts on the following...
Would you consider beam B2 in the attached sketch to torsionally/rotationally brace beam B1?
Details:
B2 is timber and fixed to main lateral system.
B1 is a steel I-beam and is part of a moment frame, hence bottom flange compression.
My take on...
Hi all,
I have somehow managed to make the selection cursor bubble really big which makes it a pain to select nodes and members. Anyone know how reduce??
Thanks in advance
Hi all,
It is proposed to have a storage mezzanine built into an existing single storey tilt panel building. It only partially covers the plan area of a unit and its attachment to the existing building is to 2 parallel tilt walls (at 3m elevation of 6m tall panels), which I'm happy to utilize...
Hi all,
This clause states
"The nominal shear capacity of the screw shall be determined by testing in accordance with Section 8 and shall not be less than 1.25 Vb where Vb shall be calculated in accordance with Clause 5.4.2.3." CL5.4.2.3 relates to tilting and hole bearing, which depends upon...
I have a scenario where a steel bracing frame is situated on a long strip footing. The frame columns are 2m apart and impart a overturning force of 70kN (1 up , 1 down) each to the footing, which is for other purposes approx. 15m Long. Frame situated approx. central along length of footing...