I'm trying to calculate the flow of nitrogen through an orifice and wanted to check to see if my method is correct. The inlet of the orifice is at 1.38 Barg and the outlet is unrestricted flow to atmospheric conditions at 21 C. The cross sectional area of the pipe is 1.78x10^-5 m^2. I have been...
I'm trying to determine the amount of nitrogen flowing to various pieces of equipment in SCFM. 1/2" drops lead to pressure gauges just upstream of each regulator. ~5 feet of plastic tubing connect the regulators to the equipment. Inlet and outlet pressures range from 20 PSIG to atmospheric. The...