Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SDETERS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Delikado
  • Content: Threads
  • Order by date
  1. Delikado

    PWHT on P1(ASMEIX) material with wall thickness >25mm

    Hello Experts, As per ASME B31.3 2016 table 331.1.3, P1 materials are exempted to mandatory PWHT and for nominal wall thickness above 25mm an additional pre-heat of -95deg C is required. Is the exemption only applicable provided the provisions in paragraph 331.2.2 "Exceptions to Basic...
  2. Delikado

    Positive material identification (PMI) on Alloy Steels

    Dear Experts, I would like to get your professional opinions/answers with regard to subject. According to Russian Regulation: "Positive material identification shall be performed for all welded joints of alloy steel pipelines of Category I, or transporting media of Group A(a), or operating...
  3. Delikado

    Piping Integral attachment

    Dear Experts, Hello again, regarding Integral attachment for piping like support shear lugs(welded to pipe), any specific NDT requirements for this welds according to ASME B31.3? Regards, Delikado Expecting life to be fair on you because you're a good person, is like expecting an angry bull...
  4. Delikado

    Pre-Heating of Carbon Steel pipe with 20 mm wall thickness and at low ambient temperatures

    Dear Experts, Our client has this requirement in their WPS regarding pre-heating of A333Gr.6 and A671 material(pipe) with nominal wall thickness of 20mm-50mm to min.temp of 100-120 deg.C and pre-heat maintenance is also required by using resistance heaters/gas torches, maximum interpass...
  5. Delikado

    Weld Location and Distance

    Dear Experts, As per Russian Standard GOST 32569:2013 paragraph6.8.1 The distance between the adjacent annular butt-welded joints shall not be less than a threefold value of the nominal thickness of the parts to be welded, but not less than 100 mm for diameters up to and including 219 mm, not...
  6. Delikado

    Pipe Distortion due to Weldolet Welding

    Any recommendation on how to practically repair/correct a banana-warped pipe due to weldolet welding?Heat treatment? and does anybody knows about allowable distortion mentioned in ASME or EN? I searched already but was not successful though. I would appreciate for any advice.

Part and Inventory Search