I am currently checking an fixed tube heat exchanger design with the help of Compress as per Section VIII .
Since I am restricted to using standard pipes due to availability for Shell and Nozzle material, the MAWP of the said HX is 3 times higher than that of the design pressure and the nozzle...
Hello,
I need to establish a relation between minimum leak path dimension (Section IX) and minimum weld throat (Section VIII Div-1 UW 20) for Tube to tube sheet joint. Does anyone have any literature pertaining to it?