Dear All
I am not clear on upper limit of1.4 on the second to primary moment ratio.
M2nd-order=< 1.4M1st-order. the question is which moment ( M2nd-order (Pdelta(big))(Sideway only) or M2nd-order (P delta(big)+delta(small))(Sideway+slenderness effect) )to compare with M1st-order?
Thank you
Dear Everyone
I am not sure about this section in ACI318-19"6.7.1.3 The cross-sectional dimensions of each member used in an analysis (Linear elastic second-order analysis) to calculate slenderness effects shall be within 10 percent of the specified member dimensions in construction documents or...
Dear all
I have question on design load of Helipads as per ASCE7-16
1.Should we apply load of Helicopter only (1.92kPa/2.87kPa)? and how about effect wind from Helicopter? [Pic-1]
2.Other section 4.11 in ASCE state that 2 kinds of apply concentrated load: 2 single concentrated loads (2.44m)...
Hello everyone
please explain me about the Note: ' * IN CASE OF THE DEPTH OF FOUNDATION AND TIE GIRDER ACCOMMODATE DEVELOPMENT LENGTH OF COLUMN, STANDARD 90 HOOK SHALL NOT BE APPLIED" ?
thank you
Hello All
How to model Beam with 2 Difference Level Slab in Etabs? and make sure it work properly as real-life structure? (as attachment)
Thank you!
https://files.engineering.com/getfile.aspx?folder=1f72007e-a585-4dbf-8baa-b3bbd7fcb24b&file=2_Difference_Level_Slab.png
Dear all
I don't understand these points:
Table 6.6.3.1.1(a)-[---] at Factored Load Level
Table 6.6.3.1.1(b)-[---] at Factored Load
What means of these words "Factored Load Level" and "Factored Load" ?
Please see attachement.
Thank you.
Dear everyone
If I do run non-linear static analysis for capture P-Delta and then let’s the program (Etabs) design/check the capacity of column, instead using Moment Magnifier. Should I reduce the moment inertia of members as per ACI?
Another question
In Global Analyses (Drift Check), Should I...
Dear Alls,
I have faced this warning in Etabs2016, How can I solve it?
For Slab Combination and Wall Combination
"
----------------------------------------
BASIC STABILITY CHECK FOR FORCE-CONTROLLED NONLINEAR STATIC LOAD CASES:
NUMBER OF NEGATIVE STIFFNESS EIGENVALUES SHOULD BE ZERO FOR...
Dear Everyone!
I have a 8F Building project design with Swimming pool on Top,How can we applying water pressure of Swimming pool in Modeling (Etabs)?
as I know water pressure divide in to 2 : Static and Dynamic.
Thank you.
Dear everyone!
Could you tell about torsional constant modifier value in Etabs to as code requirement?
when reduce it, effect on other local and global stability design?