  1. Kovan A.

    Shoud we apply this is from ACI 318 in ETABS

    Hi As i see rarely someone check wither the shear wall is cracked or not then apply stiffness modification accordingly for the shear wall, as you know we should apply F22=0.35 for cracked wall and F22=0.7 for uncracked wall (default axes orientation)? we check this by creating a model and...
  2. Kovan A.

    Can we Drift limit and stability index only by RSA?

    Hi Is it enough to check drift limit, stability index only by RSA or we need to check those for Equivalent lateral force too, when both method permitted in table 12.6-1 for analyzing the building? what about when only RSA method permitted for analyzing the building (ELF not permiited) do we...
  3. Kovan A.

    Risk Category for a 30 story residential building

    Hi In IBC 2018 for this kind of building i only find that if its occupant load >5000 it will be Risk category III otherwise it will be Risk category II, am i right? Occupant load of this building is around 2000 should i choose Risk Category II for this building Base04 – Base01 (Storage...
  4. Kovan A.

    Allowable gross bearing capacity for checking pressure under mat foundation of 35 stories building!

    Hi In soil report we only get the Net allowable bearing capacity and we use that Net allowable bearing capacity which is usually around 200 kN/m2 at depth of 7-9m (soil type is very stiff to hard light brown to grayish brown fat silty CLAY), which is larger enough for building around 12 stories...