  1. ElecEE8

    Why we need separate PTC device or module for VFD driven Ex Motor (LV)?

    Dear All, Can anyone explain why we need a separate PTC device or module for VFD driven Ex Motor (zone 1& 2 classified area) for the thermal protection? I received this requirement from my client. Currently our design is without this device means the PTC signal from Ex Motor going into the VFD...
  2. ElecEE8

    Aluminuim cable vs Copper cable comparision

    Dear All, Needed your technical and commercial aspects on the subject for distribution system and oil& gas application only. I am searching your feedback on both aspects technical and commercial also pro & cons. Appreciate your feedback. Thanks ElecEE8
  3. ElecEE8

    Single bearing motor for Compressor package - solo run test

    Dear All experts, The question here I have is, how we operate or maintain the solo run test and any others low speed maintenance activities for the single bearing 11kV motor (1.3MW)? I mean to whenever we have a decoupling condition of the motor from its compressor package. The motor has single...
  4. ElecEE8

    Sample Coil Test (Motor, Generator & Transformer)

    Hi All, Anybody can advise me, what is the right timing to perform and witness sample coil test of the machines (motor, generator also transformer)? I mean to factory acceptance test (FAT).
  5. ElecEE8

    Insulation bearing for MV/HV motors

    Is it mandatory to provide insulation bearing for all MV and HV motors? There are regularly failure reported in oil&gas and petrochemical plant on bearing failure of MV and HV motors nowadays. Any best practice available in design & engineering /or lesson learnt in your place, please share.
  6. ElecEE8

    What is different between CB utilization category A & B? How to select? Any criteria?

    As per below statement: "Circuit breakers shall have utilization category A, except for circuit breakers feeding sub-distribution switchboards and require selectivity by means of an intentional time delay shall have utilization category B" Why normally CB utilization shall be Cat. A and for...