Dear All,
I am analyzing the Internal partition non-load bearing wall (Unreinforced) for lateral wind load as per Euro Code-6. I am having a doubt about the Bottom edge support condition. I found some examples 4 edge supported panels using bottom edge as continuous and sides and top edge as...
Dear All,
I am having a cantilever canopy long span > 5 m. Design concept is a tube with Pretension cable (30 kN) rod as shown below image.
There are lot of high tensile cables available in market, but I want some economical solution.I Was thinking to use 10.9 grade rod as pretension rod...
Dear All,
I am designing a rack system for storing the Building façade Aluminium profile. I tried to find the live load from the codes but didn't found any reference. I checked ASCE-7, IBC and BS6399 but didn't found. Most of the codes having recommendation for Books and files and industrial...
Dear All,
I am trying to analyse one Rectangular steel tank (water) having size approx. L X W X H = 8 x 1.5 x 2.2 m. I modelled it in STAAD Pro and applied loads as below:
1. Side walls hydrostatic pressure triangular
2. Base uniform pressure with intensity H x water density.
The tank will...
Dear All,
I am designing a foot over bridge crossing the road (State Highway) and all connections are bolted connections. I am having a doubt about the selection of bolt. Shall I go with 8.8 Grade bolt or HSFG bolt. Is there will be too much Vibration due to pedestrian movement in bridge? I...
Dear All,
I am having a doubt about bolt torque.
I am designing a steel structure in that I have M-24 (24 mm diameter) bolt 8.8 grade with maximum tension of 125 kN. Is it mandatory to calculate torque for this case or simply I can follow the Standard torque chart available? Is torque value...
Dear All,
I am designing Aluminium CW, and I am planning to take continuity for moment at the floor connection. CW is for for middle east region, there is a expansion gap at every floor . In same expansion joint I am planning to insert steel sleeve with some considerable length so it will...
Dear All,
I am having doubt about consideration of direction factor in wind load calculation by BS6399-2. Please check the attached steps and let me know about considerations.
Like this I need to calculate for every direction ? means N,S,E,W?
Dear All,
I am designing s Space frame which is having an oval shape opening, due to opening space frame is behaving like cantilever. That's why to provide good stability we provided cantilever truss from columns as shown below. The space frame is supported on truss as shown below. Here steel...
Dear All,
Is it possible to make roller Support carrying bending moment? If some one is having real life example please share. And please share the design considerations also.
Dear All,
I need to refer for canopy wind pressure calculations- COOK, N.J. The designer’s guide to wind loading of building structures. Part 2: Static structures London: Butterworth Scientific, 1985.
If some one is having softcopy or link please share.
Dear All,
I am designing a space frame which is supported on steel columns. there is a central architectural feature as well. when I am modelling all structure in one model and running seismic analysis, then central architectural feature is taking to much load and members are failing (due to...
Dear All,
I am designing a truss to column connection. I need your comments about connection. Two options of connection has shown below. which one will be the structurally sound.
Connection-A
Connection-B
In connection A there is eccentricity but I can connect both bracing and bottom...
Dear All,
I am designing a Curtain wall (Mullion and Transom system) . Contractor has to do mock up testing for curtain wall. Now testing company asking Seismic/racking Displacement value for Curtain wall. as per project specification its return only 3.5 Cycles for horizontal racking . SO...
Dear All,
I am designing a poly carbonate sheet partition which is having a height of 2.8 m in car wash area. Polycarbonate sheet has been supported by Square hollow section of size 80x 80 x 2 mm SS materiel at every 2 m of spacing. Problem with contractor is he already fabricated the Box...
Dear All,
I am designing a Steel Skylight in which beam supporting skylight has been connected with each other by a Hollow circular disc As shown in image below. All member are RHS/Tube 160x80x5 mm. each member is carrying major moment, Major shear and axial Compression/Tension. I am looking...
Dear All,
I need to know allowable Deflection limit for Aluminum/steel perforated decorative sheet due to wind. Any code BS, EURO american will be okay. If any body knows the value or code reference please share.
Dear All,
I am trying to analyse and design a Tension rod system for horizontal skylight with tension rod at top and bottom. The concept is given by consultant. But I am getting difficulty in analysis and design. My question is which element I have to consider Either tension or cable while...
Dear All,
I need to model cement Mortar in one software, please suggest me the E value I should assign for that. I Searched a lot but not getting. Please suggest E value for Normal mortar of Proportion in range of 1:3 to 1:4 and normal water content.
Regards,
Sigma