  1. LJP1

    TCP Port remote testing "Appliance"

    I am looking for ideas to have a relatively inexpensive and simple hardware device that can be sent to the field to test an Ethernet port for proper TCP port connection rights. Application is to pre-test and verify router, switch and firewall rules have been properly setup for a device, with...
  2. LJP1

    Loss Allocation to multiple resources on a bus.

    Looking for advice and recommendations on properly allocating KW and KVAR losses across multiple transformers sharing a transmission line and then further allocate each transformer line loss share to its related resources/feeders under each transformer. Assumptions - 1. Three transformers...
  3. LJP1

    Form 5, Two Wattmeter Method secondary vectors for testing.

    I’ve watch several Two-Wattmeter Method videos, including this series (3 parts starting with this one) and I have some questions to take the topic a bit farther and to better understand the vectors, specifically when CTs and PTs are in the mix. Furthermore, my confusion and frustration relates...
  4. LJP1

    Equations or Programs for HP Calculators?

    I used to use an HP41C calculator years ago. I am now studying to take PE and dusting off my RPN skills with a HP35S (NCEES approved). Can anyone tell me the pros/cons of using equations versus programs; when best to use either method? Also, does anyone have a good resource of POWER equations...
  5. LJP1

    NGR rating calculation when used with with wye-g/delta grounding transformer

    Need help with help with NGR rating for Option#1 re: EPRI Technical Brief_Effective Grounding and Inverter-Based Generation. How to properly calculate current through NGR when connected to neutral of Wye winding of Wye-g/delta(not a zig-zag) grounding transformer. What is valid impedance model...
  6. LJP1

    Line Loss Compensation for Metering

    I have a wind farm generation & tie-meter design where the meter location is at a wind farm and the point-of delivery for LBA and PPA settlements is several miles down a radial 345kV transmission line (at bus of transco). A few loss compensation questions have come up. Line loss only, no...
  7. LJP1

    Form 5 (2-element) metering with three(3) wye-connected PTs

    I am replacing a older Form 45S (Elite) meter with a Form 5S (SEL734/5) type meter in a 69kV substation using SEL's recommended Form 5 wiring method. The application is measuring power on a wye-grounded side of transformer. The meter has two (2) dedicated CTs. There are three (3) PTs...