Greetings
I would like to check with you is there any sizing calculation available for air vents (at top of sprinkler riser).
I have checked NFPA13 and couldn't find anything other than 15mm size mentioned for manual air vents.
Would it be possible to get your valuable advise?
Thank You.
Dear Experts,
Kindly confirm whether emergency lighting is required for the padel court and basket ball court areas of the indoor stadium/play area.
Thanks in advance.
Dear Experts,
The diagram below depicts the proposed single interlock pre-action (+dry pendent, as directed by project consultant) for a cold storage area.
The detection portion is handled by the VESDA system. (The pre-action system does not have a control panel)
Kindly take a look at the...
Dear Experts,
Please clarify whether an emergency lighting system must be linked to the fire alarm system in the building.
Anyone who can provide NFPA or IBC references is greatly appreciated.
Thank you!
I was wondering if anyone could help me with the selection of NEMA enclosure, based on the following specification.
NEMA2/NEMA3/something else?
Thank you!
Dear Professionals,
The below two sentences are for qualifying our quotation for a project.
Please be noted that, design drawing # DRG-01 shows X capacity of equipment which is inadequate for the project requirement. Therefore, we propose Y capacity in our offer.
Please be noted that...
Dear Experts,
I am looking forward to getting suitable stem/steering wheel arrangement which can be operated from above the tank as shown in below.
Really appreciate if anyone can advise on the following:
-Suitable valve for this kind of arrangement
-Suitable stem/steering
-Suitable position...
Dear Expert,
Is there any tricks to get dots in-between text, in excel sheet?
Text should be left and right aligned as shown below.
Thanks in advance :)
Dear Experts,
I am looking for an isolation valve which is suitable for isolating underground fire water tanks as shown in below picture.
Kindly share your thoughts.
-Intended for fire water tank isolation for cleaning
-Designed to operate while submerged
Thanks in advance.
Dear Experts,
Most of the manufactures literature shows that photoelectric detectors installed for maximum area coverage of 250 ft² (23.2 m²) per detector.
Any idea where does the 250 ft² (23.2 m²) come from?
NFPA-13-2019, Section 16.9.8.5 states that: Means shall be provided downstream of all pressure reducing valve for flow test at sprinkler system demand.
However, there is no further information available on how it can be accomplished. Kindly share your thoughts on this.
Thank you.
Dear Expert,
Kindly advice on starting from which pipe size clevis hanger should be used.
I have found nothing on NFPA-13, appreciate any input.
Thanks in advance.
The below specification id captured from master specification and being copy pasted in many projects. Now, can anyone explain me how the below highlighted 100% cylinder is going to work as an extra material if there are rooms with different volume.
Any input on this much appreciated. Thank You!
Dear Experts,
We have a tank farm project which is intended to store edible oil as follows:
(1) Storage : Different types of edible Oil
(2) Flash point of stored oil : Ranging from 250 degC to 325 degC (482 degF to 617 degF)
(3) Classification of liquid as per NFPA30 : Class-IIIB
(4) Type of...
Dear Experts,
One of the project specification calls for seismic restrains/bracing comply with NFPA13 requirement.
Based on my understanding of NFPA 13 seismic requirement, I feel cable type restrains / tension only bracing is the simplest way to get this done.
Kindly share your thought on...